background image

INSTALLATION

6

DUCTLESS CONVERSION

Ductless conversion is intended for applications where an exhaust duct work is not possible to be
installed. When converted, the hood functions as a "purifying" hood rather than an exhaust hood.
Fumes and exhaust from cooking is drawn and filtered by a set of optional Carbon Filters. The air
is then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing
new duct work, if possible. The hood is most effective and efficient as an Exhaust unit. Only when
the exhaust option is not possible should you recourse to converting the hood into a "purifying"unit.

When converted to be a "purifying" unit, a set of Carbon Filters are required on top of its standard
Metal Filter set. Order according to its Part number below. The standard Metal Filters are intended
to capture residue from cooking and the optional Carbon Filters help to purify fumes exhausted
from cooking for re-circulation.

Carbon Filters (Required)

Ducting

Hood Model:

Part No.   

Filters in pkg.

1. Purchase ductless Charcoal Filters as follow:

2. Remove metal filters on hood. Clip

carbon filters onto each slot opening.

3. Re-install metal filters.

4. Turn on filter change indicator on 

control panel (refer details pg. 7)

5. Carbon Filters must be replaced after 

every 120 hours of use (or approximately 
every 2 to 3 months based on the average 
of 1-2hrs. of daily cooking time). The 
microprocessor in the controls when set,
will count elapsed usage time and indicate
when carbon filter replacement is required 
every 120 hrs.

ZML-M90S/G

ZOF-CO22

2

ZML-E42S/G

ZOF-CO22

2

1. Install a 6" straight pipe and a "T" connector/ 

or a 90 elbow to divert air through louvers on 
duct cover.

2. You may also order our air diverting duct kit; 

call 1-888-880-8368.

6" straight pipe

wall pipe strap

6" T connector
or 90 elbow

Summary of Contents for ZML-E42S/G

Page 1: ...RU GHWHUJHQWV 6XLWDEOH IRU XVH LQ KRXVHKROG FRRNLQJ DUHD 51 1 72 5 8 7 5 6 2 5 1 723 5 6 5 D 1HYHU OHDYH VXUIDFH XQLWV XQDWWHQGHG DW KLJK VHWWLQJV RLORYHUV FDXVH VPRNLQJ DQG JUHDV VSLOORYHUV WKDW PD LJQLWH HDW RLOV VORZO RQ ORZ RU PHGLXP VHWWLQJV E OZD V WXUQ KRRG 21 ZKHQ FRRNLQJ DW KLJK KHDW RU ZKHQ IODPEHLQJ IRRG LH UHSHV 6X HWWH KHUULHV XELOHH 3HSSHUFRUQ HHI ODPEH F OHDQ YHQWLODWLQJ IDQV IUHTXH...

Page 2: ...LQJ HTXLSPHQW PDQXIDFWXUHU V JXLGHOLQH DQG VDIHW VWDQGDUGV VXFK DV WKRVH SXEOLVKHG E WKe 1DWLRQDO LUH 3URWHFWLRQ VVRFLDWLRQ 1 3 DQG WKH PHULFDQ 6RFLHW IRU HDWLQJ 5HIULJHUDWLRQ DQG LU RQGLWLRQLQJ QJLQHHUV 6 5 DQG WKH ORFDO FRGH DXWKRULWLHV F KHQ FXWWLJ RU GULOOLQJ LQWR ZDOO RU FHLOLQJ GR QRW GDPDJH HOHFWULFDO ZLULQJ DQG RWKHU KLGGHQ XWLOLWLHV G XFWHG IDQV PXVW DOZD V YHQW WR WKH RXWGRRUV 51 1 72 5 ...

Page 3: ...al Mounting the hood Ductless Conversion Carbon Filters FEATURES CONTROLS Touch controls features Advance display functions Filter change indicator Filter clean indicator MAINTENANCE Cleaning Lights replacement WARRANTY Coverage exceptions 1 1 2 3 3 4 5 6 6 7 7 7 8 7 9 10 11 12 ...

Page 4: ...o use calculation on right to compute total available duct run when using elbows transitions and caps ALW A Y S when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer R educe duct size as far away from open ing as possible If turns or transitions are required ...

Page 5: ...ng attics or garages All exhaust must be ducted to the outside Use Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or DuctTape Some Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap WARNING FIRE HAZARD ...

Page 6: ...s appliance Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable lockin...

Page 7: ...cing out for the front and sideways for the rear as shown on diagram Attach support U bracket 4 Slide telescopic duct covers onto the top of the blower unit 5 Attach duct work to the ceiling and position the electrical 6 Lift blower unit and fasten to Ceiling Plate lock tabs on support frame into slots on CeilingPlate secure support frame to Ceiling Plate with screws provided 7 Connect duct work a...

Page 8: ...INSTALLATION Mounting the Range Hood 7 Locate cover panel onto top of intake unit then attach assembly to blower unit using supplied metal tabs Secure with screws 8 Reinstall diffuser panels before installing filters ...

Page 9: ... The standard Metal Filters are intended to capture residue from cooking and the optional Carbon Filters help to purify fumes exhausted from cooking for re circulation Carbon Filters Required Ducting Hood Model Part No Filters in pkg 1 Purchase ductless Charcoal Filters as follow 2 Remove metal filters on hood Clip carbon filters onto each slot opening 3 Re install metal filters 4 Turn on filter c...

Page 10: ... and possible clogs Blower On Off Adjust 6 Speed Levels 15 Min Delay Off Lights On Off Hold to Dim Display Speed level Delay Off Indicator Filter Clean Change 1 1 2 2 3 3 4 4 5 5 The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency If improperly maintained residue from cooking will sift though filters and cause damage to hood bl...

Page 11: ...when carbon filter replacement is needed every 120 hrs Setting the Filter Change Reminder When Off hold for approx 5 seconds The display will change from exhaust mode to purifying mode carbon filters used this indicates that the elapse timer function is switched on and Carbon Filters are used Filter Replace Indicator When the display starts flashing the Carbon Filters requires replacement after 12...

Page 12: ...0 hrs of use Filters can be cleaned by hand or in a dishwasher with non abrasive soap Heavily soiled filters should also be soaked in grease cutting detergent such as 409 or its equivalent prior to cleaning Filter Clean Reminder When flashes on display the metal filters installed are required to be cleaned This will occur after every 30 hours of use Re setting Function Reset the Filter Clean Remin...

Page 13: ...Filters fitted by the factory are intended to filter out residue and grease from cooking It need not be replaced on a regular basis but are required to be kept clean Filters should be cleaned after every 30 hours of use Use the Filter Clean Reminder function on the controls to determine when filters require cleaning ref page 8 Remove and clean by hand or in dishwasher Spray Formula 409 or equivale...

Page 14: ...lass suction cup approx the diameter of the bulb and turn Replacement bulbs are available at specialty lighting stores Purchase type JDR E27 50W halogen bulbs Or to order bulbs please call our service center 888 880 8368 or online parts store www zephyronline com CAUTION Light bulb becomes extremely hot when turned on DO NOT touch bulb until switched off and cooled Touching hot bulbs could cause s...

Page 15: ...equipment of other manufacturers Repaired or modified by anyone other than Zephyr s Authorized Agents What is Not Covered Consumable parts such as light bulbs filters and fuses Services outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and wear due to imprope...

Page 16: ...roof of purchase with date ready for warranty issues Or write to Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco CA 94124 TO OBTAIN SERVICE UNDER WARRANTY or any Service Related Questions please call ...

Reviews: