background image

6

www.zephyronline.com

Duct  pieces 

Total

Equivalent  number

length  x used      =

3- 1/ 4” x 10”

Rect.,

straight

1 Ft.           x (      )   =

Ft.   

 

 

 

 

 

3- 1/ 4” x 10”

Rect. to

6” round

transition

5 Ft.           x (      )   =

Ft.  

 

3- 1/ 4” x 10”

Rect. to

6” round

transition

90

0  

elbow

20 Ft.         x (      )   =

Ft.  

 

6”, 7”, 8”, 10” 

Round,

90

0  

15 Ft. 

        

x (      )   =

Ft.   

6”, 7”, 8”, 10”

Round,

45

0  

9 Ft.           x (      )   =

Ft.   

Ft.   

6”, 7”, 8”, 10” 

Round,

straight 

1 Ft.           x (      )   =

Ft.   

Subtotal column 1 =

Duct  pieces 

Total

Equivalent  number

length  x used      =

6”, 7”, 8”, 10”

Round, wall 

cap with 

damper 

30 Ft.         x (      )   =

Ft.  

 

 

 

 

 

 

 

Ft.   

Ft.   

Ft.   

6”, 7”, 8”, 10”

Round

roof cap 

30 Ft.         x (      )   =

Ft.  

 

 

 

Subtotal column 2 =

Subtotal column 1 =

Total ductwork      =

Maximum Duct Length: 

For satisfactory air movement,

the total duct length   

   

should not exceed 100 equivalent feet.

6” round to

3- 1/ 4” x 10”

rect. 

transition

1 Ft.           x (      )   =

Ft.  

 

6” round to

3- 1/ 4” x 10”

rect. 

transition

90

0  

elbow

16 Ft.         x (      )   =

Ft.  

 

7” round to

3 1/ 4” x 10”

rect. 

transition

8 Ft.           x (      )   =

Ft.  

 

7” round to

3- 1/ 4” x 10”

rect. 

transition

90

0  

elbow

23 Ft.         x (      )   =

Ft.  

 

elbow

elbow

7” to 6” or

8” to 7” Round 

tapered 

reducer

25  Ft. 

x (      )   =

Ft.  

3- 1/ 4” x 10”

Rect. 90

0

elbow

15 Ft.         x (      )   =

Ft.  

3- 1/ 4” x 10”

Rect. 45

0

elbow

9 Ft.           x (      )   =

Ft.  

3- 1/ 4” x 10”

Rect. 90

0

flat elbow

24 Ft.         x (      )   =

Ft. 

 

3- 1/ 4” x 10”

Rect.

wall cap

with damper

30 Ft.         x (      )   =

Ft. 

 

 Ft.         x (      )   =

Ft. 

 

15

6”, 7“, 8”

Round 

in-line 

damper

Installation – 

Ducting Calculation Sheet

Summary of Contents for ZRG-E30AS

Page 1: ...Use Care and Installation Guide Model Number Serial Number www zephyronline com Roma Groove ZRG E30AS ZRG M90AS JAN20 0101 Zephyr Ventilation LLC ...

Page 2: ...www zephyronline com ...

Page 3: ...d Specifications 9 Mounting the Hood 10 Ductless Recirculating 11 FEATURES CONTROLS ICON Touch Controls 12 13 Bluetooth Controls 14 15 MAINTENANCE Hood Filter Cleaning 16 LED Light Strips 17 ACT CONVERSION 18 WIRING DIAGRAM 19 TROUBLESHOOTING 20 21 LIST OF PARTS ACCESSORIES 22 WARRANTY 23 PRODUCT REGISTRATION 24 Table of Contents ...

Page 4: ...r the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c...

Page 5: ...ed electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ...

Page 6: ... limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If th...

Page 7: ...ilters 1 LED light strip 1 6 in round backdraft damper pre installed 2 Bluetooth Stereo Speakers pre installed 1 Hardware package PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable locking connector if required by local codes Duct cover extension kit Z1C 00RO 3 Wire Nuts 6 M6 x 1 4 M4 x 8 HARDWARE PACKAGE CONTENTS ...

Page 8: ... Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 roundto 3 1 4 x 10 rect transition 900 elbow 16 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 8 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 900 elbow 23 Ft x Ft elbow elbow 7 to 6 or 8 to 7...

Page 9: ...performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 21 for part number and ordering information DAMAGE SHIPMENT INSTALLATION Please fully inspect unit for damage befo...

Page 10: ...recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options roof pitch w flashing cap side wall cap w gravity damper soffit or crawl space blower housing ductless recirculation side wall cap w gravity damper blower housing blower housing blowe...

Page 11: ... STANDARD min ducted 27 min recirc 32 max 50 Z1C 00RO EXTENSION min ducted 42 min recirc 47 max 80 5 3 4 5 3 4 3 1 4 FRONT VIEW SIDE VIEW TOP VIEW Bluetooth Stereo Speakers 9 1 2 4 5 8 2 3 8 30 2 3 4 36 4 7 8 11 7 8 Installation Hood Specifications ...

Page 12: ...Mark the mounting spread vertically until a cross has been formed to determine the exact placement of the M6 x 1 screws 8 Fasten 2 M6 x 1 screws into the studs on line B but do not fully tighten them NOTE Wood blocking may need to be added behind the drywall if no studs are present Wall anchors may also be used but check local codes for compliance Failure to use suitable wall anchors and screws to...

Page 13: ...ATING KIT REQUIRED IF NO DUCTING IS USED Kit includes the charcoal filters and the air diverter plate Hood Model Part No Filters in pkg ZRG ZRC 00RG 2 1 Purchase the recirculating kit per the part number above 2 Secure the air diverter plate to the wall below the duct cover bracket with two screws Run the 6 ducting from the top of the hood and secure it to the air diverter plate FIG C 3 Remove the...

Page 14: ...lay Off Function is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and regulations To verify the maximum fan CFM With hood off hold the Button for two seconds If all five fan speed indicators illuminate default maximum CFM If four fan speed indicators illumina...

Page 15: ...recirculating hood To enable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators will illuminate for three seconds confirming the Charcoal Filter Replace Reminder is enabled To disable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators will blink two time...

Page 16: ...al tone beeps and 1 high pitched beep will be played if disconnecting from the speakers POWER OFF Hold the button to power off the Bluetooth speakers 4 beeps from a high to low tone will be played as an indicator 2 PLAY PAUSE BUTTON PLAY Press the button to play the audio on the paired device PAUSE Press the button to pause the audio on the paired device 3 DECREASE VOLUME BUTTON DECREASE VOLUME Pr...

Page 17: ...will be played if disconnecting from the speakers How to connect to the Zephyr Bluetooth Stereo Speakers each subsequent time after the initial connection has been made 1 The speakers can only play audio files from one connected device at a time If another device was to connect to the speakers the currently connected device must disconnect but not necessarily unpair from the speakers first Disconn...

Page 18: ...b lightly with clean cotton cloth or micro fiber cloth and buff in the direction of the stainless steel grain Baffle Filters The baffle filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher using a non phosphate detergent Discoloration of th...

Page 19: ...s See list of parts and accessories page for part s and contact information To replace LED light strip 1 Remove aluminum mesh filters 2 Remove light panel by two screws 3 Disconnect LED light strip quick connector 4 Push in the two side clips on the ends of the LED strip 5 Push LED light strip through the light panel opening Push the clip FIG F ...

Page 20: ...low the wiring diagram or in another clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if your installer enabled ACT With hood off press and hold the power button for three seconds If 5 LEDs illuminate defualt max CFM if 4 LEDs illuminate max 390 CFM and if 3 LEDs illuminate max 290 CFM When ACT is enabled the number of...

Page 21: ...19 Wiring Diagram ACT 390 CFM Fan Max 2 3A ACT 290 CFM Fan Max 1 9A ...

Page 22: ...d is not secured in place 3 Check the installation of the hood The blower is working but the lights are not 1 The LED light strip connector is disconnected 1 Connect the LED light strip connector 2 Defective LED light strip 2 Change the LED light strip 3 The switch board or control board is defective 3 Change the switch board or control board The unit turns on by itself 1 A spot light or kitchen l...

Page 23: ...e user s device 4 There are multiple errors preventing the user s device from pairing with the speaker s Bluetooth 4 Restart the user s device The user s device is paired with the hood speakers but will not connect to the speakers 1 There is an error during the pairing process 1 Forget remove the speaker s Bluetooth from the user s device and retry the pairing process 2 The user s device may be ou...

Page 24: ...ter Z0F C005 LED Light Strip 9W Z0B0042 Baffle Filter 50210034 Optional Accessories Recirculating Kit ZRC 00RG Duct Cover Extension Kit Z1C 00RO Make up Air Kit MUA006A To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 List of Parts Accessories ...

Page 25: ...All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE...

Page 26: ...your new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures warranty coverage should you need service Ownership verification for insurance purposes Notification of product changes or recalls ...

Page 27: ...Guide d utilisation d entretien et d installation www zephyronline com Numéro de modèle Numéro de série JAN20 0101 Zephyr Ventilation LLC Roma Groove ZRG E30AS ZRG M90AS ...

Page 28: ...www zephyronline com ...

Page 29: ... le conduit 8 Spécifications de la hotte 9 Montage de la hotte 10 Reprise d air sans conduit 11 COMMANDES ICON Commandes électroniques 12 13 Bluetooth Commandes 14 15 ENTRETIEN Nettoyage des filtres et de la hotte 16 Bandes lumineuses à LED 17 CONVERSION DE LA ACT 18 SCHÉMA DE CÂBLAGE 19 DÉPANNAGE 20 21 LISTES DES ACCESSOIRES ET DES PIÈCES 22 GARANTIE 23 ENREGISTREMENT DU PRODUIT 24 ...

Page 30: ...s surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et à la quantité de nourriture que vous préparez AVERTISSEMENT POUR RÉDUIRE LES RISQUES DE BLESSURE LORS D UN INCENDIE SUR LA SURFACE DE CUISSON a ÉTOUFFEZ LES FLAMMES avec un couvercle une plaque à biscuits ou un plateau de métal et éteignez ensuite le brûleur PRENEZ GARDE AUX RISQ...

Page 31: ... un installateur électricien qualifié S assurer que l installation électrique est adéquate et qu elle respecte le Code national de l électricité la plus récente édition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l électricité section 1 la plus récente édition du code C22 2 No 0 M91 ainsi que tous les codes et réglements en vigueur Si les codes permettent l utilisation d un f...

Page 32: ...ont conçues pour fournir une protection raisonnable contre les interférences une installation résidentielle Cet équipement génère utilise et peut émettre de l énergie de radiofréquence et s il n est pas installé et utilisé dans conformément aux instructions peut provoquer des interférences nuisibles aux communications radio Cependant il n y a aucune garantie qu aucune interférence ne se produira d...

Page 33: ...t 2 Filtres déflecteurs 1 Bande lumineuse LED 1 Clapet anti retour rond de 6 po pré installé 2 Haut parleurs stéréo Bluetooth pré installés 1 Pack matériel PIÈCES NON FOURNIES Conduit et tous les outils d installation Raccord de câble si exigé par les codes en vigueur Accessoire d extension de couvercle de gaine Z1C 00RO 3 Écrous de fil 6 M6 x 1 po 4 M4 x 8 CONTENU DU PACKAGE MATÉRIEL ...

Page 34: ...ect coude plat à 90º circ coude à 90º coude à 45º Sous total colonne 1 Longueur maximale du conduit d aération Pour un mouvement d air convenable la longueur totale d un conduit d aération ne devrait pas compter plus que l équivalent de 100 pieds Pièces de conduit Longueur x Nombre utilisé 6 circ à rect de 3 1 4 x 10 coude à 90º 6 circ à rect de 3 1 4 x 10 6 circ à rect de 3 1 4 x 10 6 circ à rect...

Page 35: ... de la cuisinière ainsi que la hauteur recommandée de montage de la hotte au dessus de la surface de cuisson Informez vous toujours des normes et des réglementations locales en vigueur pour toute différence par rapport aux normes du fabricant Ensemble de recouvrement de conduit disponible pour les plafonds atteignant 12 pieds Nº de pièce et information pour commander disponibles à la page 21 ENDOM...

Page 36: ...sée N utilisez que des conduits en métal pour cloison simple Fixez toutes les pièces du conduit avec des vis à tôle et isolez tous les joints avec du ruban adhésif en toile ou du ruban réflecteur certifié Quelques options pour le conduit d aération Installation Options pour le conduit d aération pente de la toiture avec solin et chapeau bouche d aeration de mur lateral avec clapet antirefoulement ...

Page 37: ... STANDARD min avec conduit 27 po min avec reprise d air 32 po max 50 po Z1C 00RO EXTENSION min avec conduit 42 po min avec reprise d air 47 po max 80 po vue de face vue de côté vue de dessus 5 3 4 po 5 3 4 po 3 1 4 po Haut parleurs stéréo Bluetooth 9 1 2 po 4 5 8 po 2 3 8 po 30 po 2 3 4 po 36 po 4 7 8 po 11 7 8 po ...

Page 38: ...po aux poutres de la ligne B Ne tournez pas les vis jusqu au fond NOTE Vous pourriez avoir à ajouter des renforcements de bois pourraient derrière la cloison sèche si aucune poutre n est présente Des dispositifs d ancrage au mur peuvent également être utilisés mais vérifiez d abord les réglementations locales avant d utiliser de tels dispositifs 8 Enlevez les deux 2 filtres à tamis en aluminium 9 ...

Page 39: ...onnels aident à la purification des vapeurs et fumées de la cuisson lors de la reprise d air ENSEMBLE DE REPRISE D AIR REQUIS SI AUCUN CONDUIT N EST UTILISÉ L ensemble comprend des filtres à charbon et un déflecteur d air Filtres et supports Modèle de hotte Numéro de pièce par paquet ZRG ZRC 00RG 2 1 Procurez vous l ensemble de reprise d air en utilisant le numéro de pièce ci dessus 2 Fixez le déf...

Page 40: ...ent est en cours d utilisation pour éteindre la hotte et annuler la fonction d arrêt à retardement Vérification de la ACT La technologie de contrôle du débit d air permet à l installeur d ajuster la quantité maximale d évacuation de pi3 min du ventilateur afin de respecter les codes et règlements en vigueur Pour vérifier la quantité maximale d évacuation de pi3 min du ventilateur Lorsque la hotte ...

Page 41: ... doit être activé lors de l utilisation du mode de recirculation d air Pour activer le rappel de remplacement des filtres à charbon Lorsque la hotte est éteinte tenez les touches et enfoncées simultanément pendant deux secondes Tous les indicateurs DEL s illuminent pendant trois secondes confirmant l activation du rappel de remplacement des filtres à charbon Pour désactiver le rappel de remplaceme...

Page 42: ... neutre et 1 un bip aigu sera émis en cas de déconnexion des haut parleurs ÉTEINDRE Maintenez le bouton enfoncé pour éteindre les haut parleurs Bluetooth 4 les bips d une tonalité haute à basse seront joués comme indicateur 2 BOUTON PLAY PAUSE JOUER Appuyez sur le bouton pour lire l audio sur l appareil couplé PAUSE Appuyez sur le bouton pour mettre l audio en pause sur l appareil couplé 3 BOUTON ...

Page 43: ...cter aux enceintes stéréo Zephyr Bluetooth chaque fois par la suite une fois la connexion initiale établie 1 Les haut parleurs ne peuvent lire des fichiers audio qu à partir d un seul appareil connecté à la fois Si un autre appareil devait se connecter aux haut parleurs l appareil actuellement connecté doit d abord se déconnecter mais pas nécessairement se dissocier des haut parleurs La déconnexio...

Page 44: ...ns le sens du grain N utilisez pas de produits à blanchir au chlore ou d agents nettoyants orange Filtres à tamis en aluminium Les filtres à tamis en aluminium installés par le fabricant ont pour fonction de filtrer les résidus et la graisse de cuisson Ils ne nécessitent aucun remplacement sur une base régulière mais doivent être gardés propres Enlevez les et nettoyez les à la main ou au lave vais...

Page 45: ...essoires à la page pour les références et les coordonnées Pour remplacer la bande lumineuse à LED 1 Retirez les filtres à mailles en aluminium 2 Retirez le panneau d éclairage à l aide de deux vis 3 Débranchez le connecteur rapide du bandeau lumineux à LED 4 Appuyez sur les deux clips latéraux situés aux extrémités de la bande de LED 5 Poussez le ruban lumineux à travers l ouverture du panneau lum...

Page 46: ...du schema de cablage ou a un autre endroit visible NOTE Apres avoir modifie la position du cavalier et branche l appareil le debit de la hotte ne peut etre modifie a nouveau Pour vérifier si votre installateur a activé la ACT Appuyez sur la touche de mise en marche et tenez la enfoncée pendant trois secondes lorsque la hotte est éteinte Si cinq indicateurs DEL s allument la hotte est réglée pour é...

Page 47: ...ntilateur 455W Thermiquement Protègè Contrôleur Bluetooth SCHÉMA BLANC NOIR P C source de courant haut parleur BODY VERT NOIR BLANC BLANC MOTEUR NOIR BLANC BLEU MARRON GRIS BLANC ROUGE JAUNE GRIS MARRON BLEU VERT BODY ROUGE JAUNE JAUNE JAUNE ACT 390 pi3 min Max du ventilateur 2 3A ACT 290 pi3 min Max du ventilateur 1 9A ...

Page 48: ...éfectueuse L appareil vibre 1 Le moteur n est pas bien fixé en place 1 Fixez solidement le moteur en place 2 La roue du ventilateur est endommagée 2 Remplacez le ventilateur 3 La hotte n est pas bien fixée en place 3 Vérifiez l installation de la hotte 4 Tableau de contrôle commande défectueux 4 Remplacez la pièce défectueuse Le moteur fonctionne mais pas les lumières 1 L ampoule LED est défectueu...

Page 49: ...m the user s device 4 There are multiple errors preventing the user s device from pairing with the speaker s Bluetooth 4 Restart the user s device The user s device is paired with the hood speakers but will not connect to the speakers 1 There is an error during the pairing process 1 Forget remove the speaker s Bluetooth from the user s device and retry the pairing process 2 The user s device may b...

Page 50: ...bon filtre Z0F C00F Bande lumineuse LED 9W Z0B0042 Filtre à chicane 50210034 Accessoires optionnels Ensemble de reprise d air ZRC 00RG SS recouvrement de conduit Z1C 00RO Kit d air d appoint MUA006A Pour commander des pièces visitez nous en ligne au www zephyronline com ou communiquez avec nous par téléphone au 1 888 880 8368 ...

Page 51: ...Un an après la date d achat originale du Produit vous êtes également responsable de tous les frais de main d œuvre associés à la présente garantie Restrictions de la garantie NOTRE OBLIGATION DE RÉPARER OU DE REMPLACER À NOTRE GRÉ LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PRÉSENTE GARANTIE NOUS NE NOUS PORTONS PAS RESPONSABLES POUR TOUT DOMMAGE INDIRECT ACCESSOIRE OU PARTICULIER RÉ...

Page 52: ...ation Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile à bien des égards C EST IMPORTANT Il assure la couverture de votre garantie si vous avez besoin de service après vente À des fins d assurance il permet de confirmer que vous êtes le propriétaire Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits...

Reviews: