5.2
Maximum power consumption - Minimum recommended conductor
cross sectional area
Hydraulic unit 7100
24 volt
Pump - Motor unit
200 A
Magnet (hydraulic unit)
2.10 A
Magnet (electric safety valve)
0.75 A
Solenoid
0.85 A
Minimum recommended conductor cross sectional area
(copper cables, plus and minus cables)
Control cable
1.5 mm
2
Supply cable, L < 8 m
35 mm
2
Supply cable, L = 8 - 15 m
35 mm
2
Supply cable, L > 15 m
50 mm
2
Battery
Min. capacity, I
min
(available for lift)
170 Ah
Min. voltage during operation, U
min
(at lift)
18 Volt
Z 2500 ( 200 bar)
Image 58.
M
aximum power consumption - Minimum recommended conductor cross sectional area
-
+
-
+
L
L
U
min
I
min
I
min
U
min
Ensure that the lift has
access to the minimum
recommended power
capacity (I
min
)
.
Some ve-
hicles have restrictions
regarding the amount of
power the lift can access
from the existing battery.
NOTE.
Summary of Contents for Z 2500-130
Page 2: ......