Z 2500-130/150
36
Cable routing
www.zepro.com
5.3
Main power cable, earth cable, main fuse and main switch
Main switch should always be mounted when cab switches (CS) are not used, for example when installing on trailers.
Main switches can also be installed in combination with cab switches (CS) if desired.
1. If the positive battery terminal is suitable for the main fuse of the lift, it can be used for mounting the fuse.
Otherwise, secure the fuse box in a suitable, well-protected place as close to the battery as possible.
2. When using the fuse box, route the main power cable from the battery to the fuse box. Prepare the cable
with cable terminals and shrink hose over the connections without connecting. Connection is described
later in section
6
.
3. On tail lifts with cable-mounted quick connector for its earth connection, connect the earth cable to the
quick connector.
4. Route the tail lift earth cable to the negative battery terminal. Fit cable terminal and shrink hose to the cable
and connect.
IMPORTANT
!
Earth connection must not be made to anything other than the negative terminal of the battery. Risk of material damage.
When installing without main switch
5. On tail lifts with cable-mounted quick connector for its main power, connect the main power cable to the
quick connector.
6. Route the main power cable from the tail lift to the fuse box/battery plus terminal. Prepare the cable with a
cable terminal and shrink hose without connecting. Connection is described later in section
6
.
Image 59.
C
onnection to the bat-
tery's positive terminal
Image 60.
C
onnection to the fuse box