20
Installation
www.zepro.com
ZHZ 500/600-850
5.11 Control devices
1. Fit the controllers in the desired locations. How-
ever, locate them such that the operator’s work-
ing position is as safe as possible, and with an
adequate overview of the load, tail lift and their
working area.
2. The distance between the vehicle’s rear edge and
the centre of the controllers must be 300-600 mm.
The distance between the controllers must be at
least 260 mm. See Fig 26.
3. Any additional controllers can be installed in an
optional location.
4. Run the controller cabling to the tail lift cable grommet.
Connection is described later in section 7.
Fig 26. Installing control devices for two-handed grip
Min. 260 mm.
300 - 600 mm.
Fig 27. Installing control device
m
WARNING!
A controller must always be fitted on the side that is facing away from traffic in motion. If there is a need for a
controller on the opposite side, a further controller must therefore be fitted. Fitting on the other side involves
increased risk of injury.