Cable routing
23
www.zepro.com
ZHZ 500/600-850
Fig 31. Battery capacity and definition of the length of the earth and main power cables
-
+
-
+
L
L
U
min
I
min
I
min
U
min
6.2
Sizing electrical systems
Ensure that the battery and charger capacity is sufficient for the product in question and that cable with suf
-
ficient cross-sectional area is used.
NOTE!
Make sure the lift has
access to the minimum
recommended current ca-
pacity (I
min
)
.
Some vehicle
models have restrictions
regarding the amount of
power the lift can access
from the existing battery.
12 volt
24 volt
Pump – Motor unit
100 A
60 A
Magnet (hydr. unit)
4.2 A
0.7 A
Magnet (electrical hose rupture valve) 1.5 A
0.75 A
Solenoid
1.8 A
0.9 A
Minimum recommended conductor cross sectional area
(copper cables, positive and negative cables)
Control cable
1.5 mm
2
1.5 mm
2
Supply line, L < 8 m
35 mm
2
35 mm
2
Supply line, L = 8-15 m
35 mm
2
35 mm
2
Supply line, L >15 m
-
35 mm
2
Battery
Min. capacity, I
min
140 Ah
110 Ah
Min. voltage during operation, U
min
(when lifting)
9 volt
18 volt
ZHZ 500-850 (140 bar)