ZS MK2
18
Rear member cut-outs
www.zepro.com
WL1 U7 U6 U5 U5 U4 U4 U3 U2 U1 U0
+
+
WL2
PA+
S5
S1+
S4
S3
S2
S1
S5+
S4+
S3+
S2+
PA-
CS+
Down
2H
Out
Down
Down
C1+
C1+
Up
Tilt
In
C2+
Up
Tilt
C3+
Up
CS
+
U1
U2
U3
U0
+
Picture 22. Temporary connection of controller
Jumper
4.2
Temporary connection of lift
When the lift is installed, it is sometimes necessary to operate the lift functions in order to change the posi-
tions of the cylinders and the 1st booms. Temporarily connect the lift to enable the lift functions.
1.
Connect the controller to the relay card.
2.
Connect earth connection (GND) and +12/24V to the quick connectors on the main power cables of the
lift.
3. When operating, connect
a cable between an available power supply connection (+) and CS on the relay
card to simulate switch CS in the On position. Remove the jumper immediately after completed opera
-
tion.
m
WARNING!
Take great care when running the lift functions, ensure nothing gets trapped, risk for personal injury
and material damage.
4.2.1 Battery maintenance
When installing the lift, when the lift is operated repeatedly, the battery charger must be used between opera-
tions to maintain the battery charge level.
The battery charger must not be connected when operating the lift. Risk of
material damage.
IMPORTANT
!
Jumper (Factory installed)
Black
C1+
White
( ), if available)
Brown
Up
Yellow
Down
Blue
Tilt
Green
In
Grey
Out
Up
Tilt
Down
Slider out
Slider in
Main power switch