WATER CONNECTION 

The system must be connected to the potable water supply network. 

 

 

If  the  system  includes  a  filtration  system,  ensure  that  all  the  filter  elements  are  properly  installed    before 
making any connection to the water supply.

 

Refer to the appropriate paragraph or instructions supplied with the filters for installation, maintenance and  

 

   expiry. 

 
It is recommended to install a valve at the water input  of the cooler, in order to isolate the system from the water 
supply whenever it is necessary. When the customer is not able to service, it is recommended to install a device that 
automatically stops water flow and  isolates the product from the water circuit (our sales department is available for 
further technical specifications). 

 

No tools are required to connect the system to the drinking water tube. Connection is carried out easily and  within 
seconds, simply by inserting the tube directly into the rapid connection located on the back/side of the product. 
This product can be supplied with ¼” rapid connections if the connections are white (or beige). 
In this case, do not use 6 mm metric tubes as these are not suitable. 
Before connecting the water tube be sure that there are no traces of impurities in the inlet rapid connection. A dust 
cap may be present, if so, it is necessary to remove it before water tube connection. 
 

The  incoming  water  pressure  must  be  between  0.250  MPa  e  0.500  MPa

.  The  flow  rate  should  not  be  less  than  3 

litres/minute. 
 

Check that the pressure remains constant even while water is being dispensed or at least that variations 
do not exceed 0.050 MPa. If this is not the case, reduce the length of the connection tube, or increase the 
internal cross-section. 

 

To ensure proper installation, it is recommended to use only certified food-grade tubes and fittings. 

 

CAUTION: If incoming water pressure is unknown,  a “water pressure reducer” must be installed and set to 
0.250-0.300MPa.  Again,  check  that  the  pressure  is  maintained  within  this  range  even  while  water  is 
dispensed, or that variations do not exceed 0.10 

MPa

 
CAUTION:  If  an  excessive  drop  in  water  pressure  is  detected  during  delivery,  switch  off  the  product 
immediately and install it strictly in accordance with the above provisions. 
Insufficient pressure causes damage to the pump in the water carbonation circuit,  continuing intervention 
of the electronic protection device and invalidation of the warranty.

  

 

(090)

 

 

Specifications for unit with inlet in brass. 

Connect the fittings (3/8” or ¼”F) to the water mains; 
Press the tap for a few seconds and wait until the flow becomes regular. 
 
 
 
 

Specifications for the waste of the water 

Connect the pipe Ø 20-22mm. to the conduct discharge. 
 

Summary of Contents for REFRESH P HPDC

Page 1: ...for which it has been designed as well as safe in compliance with applicable standards The reproduction of the contents of this manual for distribution to third parties is strictly forbidden without the express prior consent of the manufacturer Zerica S r l This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experienc...

Page 2: ...a gap of at least 5 cm on each side and 25 cm by the ventilation slots If the ventilation slots are covered the cooling system cannot operate properly and this inevitably leads to malfunctioning Do not place any objects on top of the product Caution non compliance with the above conditions causes the compressor to overheat and break leading to immediate invalidation of the warranty For proper inst...

Page 3: ...id connection A dust cap may be present if so it is necessary to remove it before water tube connection The incoming water pressure must be between 0 250 MPa e 0 500 MPa The flow rate should not be less than 3 litres minute Check that the pressure remains constant even while water is being dispensed or at least that variations do not exceed 0 050 MPa If this is not the case reduce the length of th...

Page 4: ...4 R C column tap Screw with care the tube to the inferior part of the tap without moving the black lever from place ...

Page 5: ...ust be grounded in compliance with applicable standards and laws In case of malfunctioning grounding reduces the risk of electrical shocks Connect the appliance cable to a double pole switch with a minimum of at least 3 mm distance between the contacts or using a plug which must still be accessible after installation 080 USING THE PRODUCT FOR THE FIRST TIME When you first use the product in order ...

Page 6: ...tion slots Periodically check that the ventilation slots are clear and not obstructed then remove any impurity deposited on the ventilation slots using a brush or a vacuum cleaner CAUTION Failure to clean the condenser and poor ventilation of the cooling circuit can cause the compressor to overheat and break These causes invalidate the WARRANTY and any repair cost will be charged 130 WATER CIRCUIT...

Page 7: ...AINTENANCE CHART Date of installation Customer Address Tel Installation company Model SERIAL NO RESPECT MAINTENANCE DATES DURING WARRANTY see warranty clauses Date Litres Replaced parts Service centre 200 ...

Page 8: ...e number and a description of the problem and in any event by filling out the RMA form Transport costs shall be borne by the purchaser You can get more information by contacting ZERICA S r l at the address below There may be delays in the repair or replacement of components that are found to be faulty at source in the event that they are not in stock The warranty excludes those products that I in ...

Page 9: ...9 ...

Page 10: ...ts Section 2 Limits for harmonic current emissions equipment input current less than 16A per phase CEI EN 61000 3 3 2014 o Electromagnetic compatibility Part 3 Limits Section 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current less than 16A and not subject to conditional connection Declares under its responsibility that this product Compl...

Page 11: ...lab in Modena HPDC system consisting of food grade copper components Test Report No 1201 09 issued on 11 May 2009 by G R Biochemilab in Modena Plastic fittings Test Report No 51 10 AMB issued on 10 December 2010 by Bioanalisi in Erice Nickel plated brass fittings Test Report No 51 10 AMB issued on 10 December 2010 by Bioanalisi in Erice Brass fittings Test Report No 51 10 AMB issued on 10 December...

Page 12: ...12 ...

Page 13: ...p www zerica com e mail info zerica com Total or partial reproduction is forbidden The manufacturer disclaims any responsibility for any typographical errors included in this manual It reserves the right to make amendments to own products considered necessary or useful withou jeopardising their functional features without prior notice 300 ...

Reviews: