background image

 

Betapack 4 User Manual v1 

9850-000753-00 

Page 3 of 12 

Introduction 

Thank you! 

Thank you for choosing Betapack 4 by Zero 88 to fulfil your 

lighting power needs. We sincerely hope that your new unit 

will bring you years of trouble free service. We make great 

efforts to build in reliability and serviceability at every stage 

of our development and production processes and include 

a three-year limited warranty - giving you peace of mind for 

your investment. 

Our extensive dealer network can also provide you with 

technical service and sales support in your local language 

no matter where you are in the world. If you have any 

questions, comments or problems our contact details can 

be found at 

zero88.com/support

 

Once again, thank you for choosing Zero 88. 

 

 

To remove the cover 

 

Isolate and disconnect Betapack 4 from the mains supply. 

The mains supply terminals (and output terminals on the 

hardwire version) are located under the top cover. To 

remove the top cover, remove the four screws “A” in 

Diagram 5 from the side plates. 

The Triacs (type BTA40-600A/B) are located under the 

bottom cover. To remove the bottom cover, remove the 

four screws “B” in Diagram 5 from the side plates.  

 

Diagram 1 

 

WARNING! 

Do not remove the covers without first completely disconnecting Betapack 4 from the mains supply

 

Summary of Contents for Betapack 4

Page 1: ...iaan Apparatet m tilkoples jordet stikkontakt Apparaten skall anslutas till jordat uttag This equipment is designed for professional stage lighting control and is unsuitable for any other purpose It s...

Page 2: ...ton 6 Up Down Buttons 6 Default mode 6 Channel test 6 Setup modes 6 Manual control 6 DMX Address 7 DMX Fail 7 Memories 7 Sequences 7 Preheat 8 Topset 8 Dimmer laws 8 Super user 9 Lock Unlock 9 Resetti...

Page 3: ...port in your local language no matter where you are in the world If you have any questions comments or problems our contact details can be found at zero88 com support Once again thank you for choosing...

Page 4: ...output terminals will accept wire sizes up to 6mm2 Hardwire Earth output ring tags blue crimp will accept wire sizes between 1 0mm2 and 2 5mm2 These may be replaced if larger diameter wiring is insta...

Page 5: ...embly to fall out Allow a minimum vertical spacing of 130mm between packs and between packs and other equipment A spacing of 180mm is recommended for ease of wiring and servicing For Portable Use The...

Page 6: ...ing both buttons together will reset the display to the default values Default mode If a block patch has been set see DMX Address below then the display will show the DMX start address of the block If...

Page 7: ...onds ALL memories will be cleared If memories are cleared which are used in sequences they will be removed automatically from those sequences Sequences Betapack 4 will store 3 sequences of up to 99 st...

Page 8: ...g not scaling value Select Topset by cycling through the modes using the Mode button Select required channel or A for all channels using the Up Down Arrows and press Enter to confirm Now select the to...

Page 9: ...Press the Up Down Arrows until the display shows rset Press Enter to confirm The display will flash briefly to confirm this action Betapack 4 will be reset to its default settings shown in the table...

Page 10: ...to the dim socket must be suitable for leading edge dimming Portable Appliance Testing DMX Connections Conforms to USITT DMX512 A isolated One male and one female 5 pin XLR connector DMX line is autom...

Page 11: ...on the display will be the actual temperature not the rounded figures given below Temperature Output Levels of control Main display 75 C 100 normal 75 C 80 C 100 075c 80 C 85 C 80 080c 85 C 90 C 60 08...

Page 12: ...ails Channels will switch on and off but are not able to be dimmed 1 The channel law has been set to switch Please see Dimmer Laws for further information The display is outputting a sequence of numbe...