Betapack 4 User Manual v1
9850-000753-00
Page 5 of 12
Mounting / Installation
In a 19" Rack
Betapack 4 is supplied with side brackets fitted for rack
mounting.
On a wall
Undo the four screws ‘X’ to remove the brackets, replace
the screws in the holes for future use. Stand Betapack 4
on one end. Remove the two screws ‘Y’ (see Diagram
5), fit the brackets as shown and replace screws ‘Y’. Fit
the other bracket on the other end.
The wall drilling positions are shown in Diagram 6.
WARNING Completely fit one bracket at a time.
Removal of all four screws ‘Y’ at the same time can
allow the heatsink assembly to fall out! Allow a minimum
vertical spacing of 130mm between packs, and between
packs and other equipment. A spacing of 180mm is
recommended for ease of wiring and servicing.
For Portable Use
The ‘Easicarry’ Kit, consisting of a handle and four feet,
is included with Betapack 4. To fit, remove the brackets.
Fit the handle using the screws supplied and holes ‘Z’.
Fit the four feet to the other end using the holes ‘X’ and
‘Y’. See Diagram 5.
Ventilation
Betapack 4 is convection cooled with air flowing over the
rear mounted heatsink.
Diagram 5
Diagram 6
WARNING!
Betapack 4 is designed for indoor use only.
When one or more Betapack 4 units are mounted in an
enclosed rack, a fan MUST be fitted to ensure that adequate
cool air is circulated. Up to three Betapack 4s may be stacked
in free air.