background image

Port Settings

The settings for each DMX port can be configured via the web-browser
using the following columns:

Port: The DMX port number
DMX: Green shows changing data
RDM: Tick to enable RDM
Delta: Tick to enable delta transmission (DMX frames are only
sent when network data changes)
Universe: Set the universe (port address) for this output
Rate: Sets the DMX refresh rate:
High = 24 ms frame time
Medium = 32 ms frame time
Slow = 48 ms frame time
Protocol: Select either Art-Net or sACN control over this output
Merge: Select HTP or LTP merge when 2 controllers send data
to this port (for more information, see ‘Merging’ section).
Label: Editable field for port name

DMX Workshop

DMX-Workshop™ is a fully featured network management, analysis,
configuration and diagnostics tool for lighting networks. You can
download the free software from the 

Artistic-Licence website

.

When Gateway 4 is connected to a computer running DMX-Workshop,
it should be detected and displayed as an Art-Net node (click the
‘Node List’ tab to verify this). The node can be expanded to show the
configuration and DMX output information.

Right-clicking on any entry brings up a menu that offers various
functionality:

The ‘Configure Node’ option enables configuration of the
universe number (port address), protocol (Art-Net or sACN),
sACN priority, product name and port labels.
‘Copy to clipboard’ enables all the node information to be
pasted into a support request email.
‘Merge Controls’ (selectable only on individual DMX outputs)
enables the choice of LTP (latest takes preference) or HTP
(highest takes preference) merge modes.
‘Indicators’ enables selection of normal, identify or mute for the
LED indicators. Normal is the default behaviour, identify causes
the power LED to flash, and mute turns off all the LEDs.
‘RDM Devices’ offers options for device discovery and
configuration.
‘Advanced’ leads to ‘Programme Upload’ and ‘Configure IP
Address and DHCP’.

Zero 88 - Gateway 4 - Page 12 of 16

Printed: 24/11/2020 14:34:53 ES

Summary of Contents for Betapack 4

Page 1: ... network is ready to meet your future demands Gateway 4 is appropriate for permanent installations or as a flexible adaptable rental touring tool due to it s compact rugged and scratch resistant metal design When combined with any ZerOS console Gateway 4 provides on board configuration from the console for a truly integrated system Alternatively the unit can be configured through an internal web s...

Page 2: ...E Cooper Lighting Solutions reserves the right to make changes to the equipment and specification described in this manual without prior notice Zero 88 Gateway 4 Page 2 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 3: ...manual This online manual describes the operation of Gateway 4 For an overview of the Zero 88 Online Manuals take a look at this video For detailed information on each function the manual has been divided into chapters one for each major area which can be navigated using the menu on the left hand side You can also search the manual using the search bar top right Each section or whole chapters can ...

Page 4: ...EN IEC 62368 1 2020 A11 2020 DMX is defined as Energy Source 1 SELV Revisions Change log of this manual November 2020 DE added ES July 2020 Manual Restructured ES June 2020 Manual Created ES Zero 88 Gateway 4 Page 4 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 5: ...ng instructions if using external PSU Gateway 4 is not compatible with Zero 88 s legacy console PSUs Zero 88 networking devices are designed for use within a dedicated stand alone private local area network only for the sole purpose of transmitting and or receiving nonsensitive entertainment lighting control data Although they utilize Ethernet networking these devices should not be connected to th...

Page 6: ... Gateway 4 has an RJ45 etherCON connector and supports Art Net 4 and sACN ESTA E1 31 Gateway 4 requires Cat 5 cable or better and supports 10BaseT and 100BaseT Zero 88 Gateway 4 Page 6 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 7: ...ce wiring instructions if using external PSU Gateway 4 is not compatible with Zero 88 s legacy console PSUs Please note that the product should be powered via EITHER the DC power input or Ethernet PoE but not both there is no option to fail over from one power source to the other if both are connected Zero 88 Gateway 4 Page 7 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 8: ...is used to uniquely identify the DMX data on the network Art Net allows universe numbers in the range 0 32767 sACN allows universe numbering in the range 1 63999 For the avoidance of cross protocol confusion users are advised to number universes from 1 sACN universes 0 64000 65535 are reserved When configuring sACN port numbers using Art Net you will not be able to configure between 32768 65535 Ze...

Page 9: ... streams from different IP addresses are directed to the same Port Address merging will occur If more streams are directed to the same Port Address they will be ignored sACN Merging can operate with both unicast and multicast data If two streams from different IP addresses are directed to the same universe the priority field is checked and the stream with the highest priority is output If the prio...

Page 10: ...Zero 88 Gateway 4 Page 10 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 11: ...e Gateway4 To find the IP address use DMX Workshop IP Settings The IP settings for the product are displayed in the top section of the screen The Edit control allows the static IP subnet mask and gateway to be configured DHCP operation can be selected via DMX Workshop The indicator meanings are as follows Online Green live connection between browser product Red connection lost Power Green powered ...

Page 12: ...nected to a computer running DMX Workshop it should be detected and displayed as an Art Net node click the Node List tab to verify this The node can be expanded to show the configuration and DMX output information Right clicking on any entry brings up a menu that offers various functionality The Configure Node option enables configuration of the universe number port address protocol Art Net or sAC...

Page 13: ...default the product has a static IP address in the range 2 x x x There are situations in which the user may wish to change this for example a 192 168 x x address is generally used in office environments A useful additional feature is the ability to enable automatic IP address allocation on networks controlled by a DHCP server check the Enable DHCP box to activate Squawk On a complicated network it...

Page 14: ...b leuchten die LED s grün um die DMX Aktivität anzuzeigen Online Grün Live Verbindung zwischen Webbrowser Gateway 4 Rot Verbindung unterbrochen Power Grün Netzspannung liegt an Grün blinkend Identifizierung Rot Fehler Netzwerk Gelb Link Grün ArtNet oder sACN Aktivität Zero 88 Gateway 4 Page 14 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 15: ...ely that damage will occur to your Gateway 4 Height 77 5mm Width 150mm Depth 66 2mm Weight 0 8kg Operating Temperature 0 C to 40 C Storage Temperature 10 C to 50 C Operating Relative Humidity max 80 Non Condensing IP Rating IP20 Indoor Use Only Zero 88 Gateway 4 Page 15 of 16 Printed 24 11 2020 14 34 53 ES ...

Page 16: ... our support forum at zero88 com forum or via email to support zero88 com For more urgent requests please contact Zero 88 by telephone on 44 0 1633 838088 24 hour answer service available Zero 88 Gateway 4 Page 16 of 16 Printed 24 11 2020 14 34 53 ES ...

Reviews: