background image

48.

 Leave the other links in their factory set

positions as shown on the cover.

6 Locate the four Main Board Power Supply

wires and unplug them from the Power
Supply. Plug this into the 4-way connector on
the DMX board.

7 Plug the 4 wire flying lead from the DMX board 

into the Power Supply.

FOR SIRIUS 24 ONLY:

See Figure 1

Connect the 16-way ribbon cable from the DMX
board to the connector on the Right Hand Button
Board (EM5774; on the left as shown in Figure1).
Take care to insert the connectors the correct
way around.

There are now two screen cables left coming
from under the DMX PCB. 

Plug the connector of the longer cable into the 2
way connector now fitted to the main processor
PCB as shown here.  Ensure that the colours are
fitted the correct way around as shown.  The
spare cable should be coiled up and secured out
of the way.

FOR SIRIUS 48 ONLY:

See Figure 2

Locate the 16-way ribbon cable connecting the
Outer Right Hand Button Board (situated just
above the Power Supply) to the Inner Right Hand
Button Board (EM5774). Unplug this cable from
the Inner Right Hand Button Board and plug it
into the socket on the DMX board. Plug the flying
cable from the DMX board into the socket on the
Inner Right Hand Button Board. Take care to
insert the connectors the correct way round.

There are two screened cables coming from the
DMX PCB. Plug the longer cable into the 2 way
connector now fitted to the main processor PCB.
Plug the shorter cable into the similar 2 way
connector on the slave processor PCB.  Ensure
that the colours are fitted the correct way around
as shown in Figure 2.

*

Note 

DMX Card

The screened cables are attached to the DMX PCB with Molex
connectors the RED wire on these connectors need to be
nearest the Ribbon cables.

Removing DMX Card

Should the DMX card be removed, the Sirius 48
will only function as 24 channel desk unless the
two way connectors are linked with a screened
cable.Take the cable with two way connectors at
each end and fit as shown in Figure 3. 

Note that the screen at one end of the cable is
soldered to the 0V point show in Figure 3.

Slaved desks

Where two Sirius desks (24 and/or 48) are being
used in a Master and Slave configuration, one
DMX Kit is needed for each desk, 

Each desk then 

gives its own DMX output.  The two DMX
supplies then need to be connected
independently to its own Demultiplex unit

.

Fitting the Sirius DMX Kit

Fitting the Sirius DMX Kit

 

Page 3

Figure 2: Sirius 48

Figure 1: Sirius 24

Figure 3: Sirius 48 with No DMX

Summary of Contents for Sirius 24

Page 1: ...ble for any other purpose It should be fitted and used by or under the supervision of an appropriately qualified or trained person only Zero 88 Lighting Ltd 1998 E OE Manual Stock No 73 560 00 Zero 88 Lighting Ltd Usk House Lanthanam Park Cwmbran Gwent UK NP44 3HD Tel 44 0 1633 838088 24 Hr Answer Phone Fax 44 0 1633 867880 e mail sales zero88 com web site www zero88 com Sirius 24 and 48 DMX Outpu...

Page 2: ... your desk to allow this DMX kit to be fitted All Sirius from serial number 283950 have been modified To find out if your Sirius has been modified follow instructions below to remove the back of the desk Find the microprocessor PCB two in the Sirius 48 Compare it with this sketch Is there a 2 way connector present in the position shown If there is your desk HAS BEEN modified so continue with these...

Page 3: ...e flying cable from the DMX board into the socket on the Inner Right Hand Button Board Take care to insert the connectors the correct way round There are two screened cables coming from the DMX PCB Plug the longer cable into the 2 way connector now fitted to the main processor PCB Plug the shorter cable into the similar 2 way connector on the slave processor PCB Ensure that the colours are fitted ...

Page 4: ...el simply by pressing the appropriate Channel Flash button Whenever a change is made to the output patch the outputs are re routed instantaneously 3 To turn a DMX output channel off Press the channel Flash button again For example pressing Channel 9 flash button again sets Out 001 ch This means that DMX output channel 001 is now turned off 4 When Output Patching is complete Press the Memory Progra...

Page 5: ...returns to Only if a DMX Output Kit has been installed Only if the desk was last used as a Slave Desk returns to Desk returns to See page 27 in the Sirius 24 and 48 Manual If a Sirius 48 is reading a memory card which has Sirius 24 memories in it the figures 24 will appear with these messages Press memory for or for Memory Program for Press Memory Program again for ...