3.   If it is possible to start the appliance on an alternative energy sources. 

 

4.   If the appliance fails to work on gas, check: 

a)   That the gas bottle is not empty. 
b)   That the regulator is not faulty. 
c)   If another appliance is connected to the same supply, check if it works 

properly. 

 

5.   If the appliance fails to work on 230V (Mains Electricity), check: 

a)   That the 230V supply is connected to the unit. 
b)   That there are no loose connections. 
c)   That the heating element has not burnt out. 
d)   Check if electric supply is on by feeling if hot air comes out of the top of the 

flue (chimney .This will take about 1 hour after switching on). 

 

IF THE APPLIANCE IS NOT COLD ENOUGH IT MAY BE BECAUSE:

 

 

1.   The ventilation of the absorption unit is inadequate.  Allow at least 100mm 

around Back, sides, and 600mm above. 

 

2.   The evaporator is frosted up – see Defrosting page 7. 

 

3  The gas pressure is incorrect – check the pressure regulator at the gas cylinder 

or at the jet (6) of the burner. (Page 9 – Gas burner parts list). 

 

4   If the jet (6) is blocked, remove the jet, clean with alcohol or other solvent and 

blow through with compressed air.  Never use a piece of wire or a pin to clean 
the jet. (Page 9 – Gas burner parts list). 

 

5  Check that you have the correct regulator for the cylinder and gas type that you 

are using. 

 

6     You have run out of gas. 

 

7.   The ambient temperature is too high. 

 

8.   Too many products are loaded into the freezer at one time – air must be able to 

circulate freely. 

 

9.   The lid is not properly closed or the lid seal is defective. 

 

10. The baffle has not been inserted into the chimney. (factory fitted) 

 

11. The absorption unit is leaking.   In the case of a visible leak, there will be traces 

of  a  yellow  deposit  at  the  point  where  the  ammonia  is  escaping.   If  there  is  a 
leak  on  the  evaporator  inside  the  cabinet,  a  smell  of   ammonia  may  be 
noticeable inside the bin.   If  a leak is detected, under 

 NO 

circumstances should 

you try to repair it, as the unit  is pressurized with hydrogen and may explode if 
welding  is  attempted  on  the  unit.   Call  a  qualified  service  technician.   Turn  off 
the gas or electric supply, and then empty the appliance. If it is in a small room 
or in sleeping quarters and the smell of ammonia persists remove the appliance 
to a well ventilated area.  Do not try to use it. 

 

12  There may be a drop in supply voltage, electric function only. 

Summary of Contents for GF120

Page 1: ...OR THE ZERO MODELS GF120 SINGLE LID CHEST FREEZER 2 WAY L P Gas 230V Electric ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SUPPLY HOSE IS...

Page 2: ...t 3 0 kPa Declared rate Injector size 0 42mm diameter marked 13 Gas consumption 34 2 g h Electrical Supply 230V Mains Electricity 0 320kW This appliance is a single lid single bin chest type freezer a...

Page 3: ...ANT INFORMATION FOR THE INSTALLER Only an LP gas installer registered with the Liquefied Petroleum Gas Association of South Africa may install a gas installation The installation must be installed in...

Page 4: ...before beginning to use this appliance Retain these instructions for future reference LP GAS OPERATION After initial installation after changing gas cylinder after servicing etc the gas pipes may cont...

Page 5: ...If the odour persists contact your dealer or gas supplier immediately Do not store or use gasoline or other flammable vapour and liquid in the vicinity of this or any other appliance USER OPERATING I...

Page 6: ...ps 4 5 and 6 until the flame stays alight 7 The appliance should be left running for a minimum of 12 hours before being loaded with products 8 To terminate the gas operation turn off the shut off valv...

Page 7: ...clean with alcohol or other solvent and blow through with compressed air Never use a piece of wire or a pin to clean the jet Page 9 Gas burner parts list 5 Check that you have the correct regulator fo...

Page 8: ...e is fitted with a locking device remove key to prevent accidental locking 3 Liquids or items with strong odours are well packaged 4 The ventilation of the absorption unit is not obstructed 5 You do n...

Page 9: ...ld be cleaned with a brush from time to time but make sure that the appliance is switched off and has cooled down when doing this DEFROSTING WARNING Normally the temperature of items would rise during...

Page 10: ...k the functioning of the flame failure control adjust if necessary Check the functioning of the ignition device if fitted adjust if necessary Check that the control knobs turn freely Examine the burne...

Page 11: ...ve the appliance from dwelling areas GAS BURNER PARTS LIST 1 SANS BRASS HOSE TAIL 2 FLAME FAILURE DEVICE 3 M10 NUTS 4 M10 x 3 8 UNF JET HOLDER 5 M10 x 1 JET NUT 6 JET MARKED 13 7 MIXING TUBE 8 BURNER...

Page 12: ...ration For Guarantee registration please visit https zeroappliances co za guarantee form Complete the online form and click submit Or scan the above QR code with your smart device which will take you...

Reviews: