background image

10

Author: Rudi          Version: 2.1          Revision: 1.2          Revision Date: June 2019

Check the formation of frost regularly and when it gets around 5mm thick,
defrost the appliance.

To defrost the appliance, turn it off and remove all food items.

Once defrosting is complete, clean the interior thoroughly.

IMPORTANT:

Before using the freezer again, ensure that no foreign bodies are present in the flue
chimney, or the burner (dust, insect, nests, waste paper etc.)

WARNING:

The needle valve screw used for admitting the ammonia / hydrogen filling charge to
an absorption unit is fitted to the unit’s reservoir.  It is a strictly applied provision of
the  guarantee  extended  on  the  unit  to  the  customer,  that  any  interference  with  the
filling  valve  screw  will  automatically  void  the  guarantee.    The  absorption  unit  must
not be opened, since it contains corroding chemicals under high pressure.

SERVICE NOTES

ROUTINE MAINTENANCE
It  is  recommended  that  a  suitably  qualified  person  service  this
appliance at least once a year.

-

Inspect  the  gas  hose  for  cracks  and  chafing  marks.  Test  all
connections with a suitable solution,

do not use an open flame

.

-

Check  there  is  no  smell  of  ammonia  or  any  signs of  green/yellow
crystal-like  deposits  on  the  cooling  unit  tubes.  Smell  or  deposits
indicate a leaking unit – see User instructions.

-

Check  the  functioning  of  the  flame  failure  device  (3) – adjust  if
necessary.

-

Check that the flame  failure  device  (3)  button  moves  in  and  out
correctly

-

Examine  the  burner  flame – ensure that  it  is burning  with  a  sharp
blue flame and no yellow tipping or sooting is observed

-

Check the door/lid seals are in good condition.

IN THE EVENT OF FAILURE

If the burner will not light:

-

Check  adequate  gas  supply – From  the  cylinder through  to the
burner.

-

Depress flame failure device for 15sec and try lighting with a match.

This must be done in a well ventilated area!

-

Check injector is clean – if not, clean with solvent and blow dry. Do
not try to clean with pin or similar object.

Summary of Contents for GF230IP

Page 1: ...OR THE ZERO MODEL GF230IP SINGLE LID CHEST FREEZER 2 WAY L P Gas 230V Electric ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SUPPLY HOSE I...

Page 2: ...ed rate Injector size 0 42mm diameter marked 13 or 0 Gas consumption 34 2 g h Electrical Supply 230V Mains Electricity 0 360kW This appliance is a single lid single bin chest type freezer and has a ha...

Page 3: ...on of South Africa may install a gas installation The installation must be installed in accordance with the requirements of SANS 10087 1 and any fire department regulations and or local bylaws applica...

Page 4: ...etc the gas pipes may contain some air which should be allowed to escape by briefly pressing on the safety valve knob A This will ensure that the flame lights quickly Do not press knob A for more than...

Page 5: ...er or gas supplier immediately Do not store or use gasoline or other flammable vapour and liquid in the vicinity of this or any other appliance USER OPERATING INSTRUCTIONS TO START ELECTRIC OPERATION...

Page 6: ...baffle 2 Loosen the retainer screws B2 on the element and slide the element out of bottom the chimney A1 3 Insert the burner C1 onto the bottom of the chimney A1 4 Fasten the retainer screws C2 to the...

Page 7: ...ce is connected to the same supply check if it works properly 5 If the appliance fails to work on 230V Mains Electricity check a That the 230V supply is connected to the unit b That there are no loose...

Page 8: ...ning after releasing the fail safe valve knob according to the instructions there may be two faults these being a The magnet in the flame failure device 3 is faulty b The thermocouple feeler point 6 m...

Page 9: ...and a tablespoon of bicarbonate of soda Soak a soft cloth in the solution wring it out and use it to clean out the interior of the freezer compartment and its fittings Do not use wax polish scouring p...

Page 10: ...OUTINE MAINTENANCE It is recommended that a suitably qualified person service this appliance at least once a year Inspect the gas hose for cracks and chafing marks Test all connections with a suitable...

Page 11: ...isted under Troubleshooting In the unlikely event of cooling unit failure contact the national distributor without delay IMPORTANT NOTE If there is a smell of ammonia it is advised that the user turn...

Page 12: ...12 Author Rudi Version 2 1 Revision 1 2 Revision Date June 2019 ENSURE THAT THE GAS SUPPLY HOSE IS NOT IN CONTACT WITH OR NEAR THE BURNER BOX Made in South Africa Pty Ltd...

Reviews: