8. Too many products are loaded into the freezer at one time – air must be able to

circulate freely.

9. The lid is not properly closed or the lid seal is defective.

10. The baffle has not been inserted into the chimney.

11. The absorption unit is leaking. In the case of a visible leak, there will be traces

of a yellow  deposit  at  the  point  where  the  ammonia  is  escaping.    If  there  is  a
leak  on  the  evaporator  inside  the  cabinet,  a  smell  of  ammonia  may  be
noticeable inside the bin. If a leak is detected, under

NO

circumstances should

you try to repair it, as the unit is pressurized with hydrogen and may explode if
welding is attempted on the unit.  Call a qualified service technician.  Turn off
the gas or electric supply, and then empty the appliance. If it is in a small room
or in sleeping quarters and the smell of ammonia persist remove the appliance
to a well ventilated area.  Do not try to use it.

12 There may be a drop in supply voltage, electric function only.

13. If the flame is not burning after releasing the fail-safe valve knob according to

the instructions, there may be two faults, these being:

a) The magnet in the flame failure device (3) is faulty.
b) The thermocouple feeler point (6) may not be in the flame properly.

To  rectify  this,  loosen  the thermocouple nuts (7) and adjust  the thermocouple
until  the point  is  over  the second  row  of  the  small  holes  in  the burner and re-
tighten the  nuts  on  the thermocouple. Repeat  the  starting  instructions  and
lighting procedure as laid out on page 5. (

USER OPERATING INSTRUCTIONS

–TO START GAS OPERATION

)

14. If the appliance is still not working properly, call a qualified service technician to

repair it.

SOME USEFUL HINTS

Make sure that:

1. Defrosting is carried out periodically.

2. The appliance is  clean and  dry  with  the  lid  open  when  it  is  not  to  be  used for

some  time. If  the  appliance  is  fitted  with  a  locking  device – remove  key  to
prevent accidental locking.

3. Liquids or items with strong odours are well packaged.

4. The ventilation of the absorption unit is not obstructed.

5. You do not touch the absorption unit while it is in operation as parts of it will be

extremely hot.

6. You check the condition of the gas supply tube regularly:

a) End fitting in good condition.
b) Overall appearance etc.

Summary of Contents for GF230IP

Page 1: ...OR THE ZERO MODEL GF230IP SINGLE LID CHEST FREEZER 2 WAY L P Gas 230V Electric ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SUPPLY HOSE I...

Page 2: ...ed rate Injector size 0 42mm diameter marked 13 or 0 Gas consumption 34 2 g h Electrical Supply 230V Mains Electricity 0 360kW This appliance is a single lid single bin chest type freezer and has a ha...

Page 3: ...on of South Africa may install a gas installation The installation must be installed in accordance with the requirements of SANS 10087 1 and any fire department regulations and or local bylaws applica...

Page 4: ...etc the gas pipes may contain some air which should be allowed to escape by briefly pressing on the safety valve knob A This will ensure that the flame lights quickly Do not press knob A for more than...

Page 5: ...er or gas supplier immediately Do not store or use gasoline or other flammable vapour and liquid in the vicinity of this or any other appliance USER OPERATING INSTRUCTIONS TO START ELECTRIC OPERATION...

Page 6: ...baffle 2 Loosen the retainer screws B2 on the element and slide the element out of bottom the chimney A1 3 Insert the burner C1 onto the bottom of the chimney A1 4 Fasten the retainer screws C2 to the...

Page 7: ...ce is connected to the same supply check if it works properly 5 If the appliance fails to work on 230V Mains Electricity check a That the 230V supply is connected to the unit b That there are no loose...

Page 8: ...ning after releasing the fail safe valve knob according to the instructions there may be two faults these being a The magnet in the flame failure device 3 is faulty b The thermocouple feeler point 6 m...

Page 9: ...and a tablespoon of bicarbonate of soda Soak a soft cloth in the solution wring it out and use it to clean out the interior of the freezer compartment and its fittings Do not use wax polish scouring p...

Page 10: ...OUTINE MAINTENANCE It is recommended that a suitably qualified person service this appliance at least once a year Inspect the gas hose for cracks and chafing marks Test all connections with a suitable...

Page 11: ...isted under Troubleshooting In the unlikely event of cooling unit failure contact the national distributor without delay IMPORTANT NOTE If there is a smell of ammonia it is advised that the user turn...

Page 12: ...12 Author Rudi Version 2 1 Revision 1 2 Revision Date June 2019 ENSURE THAT THE GAS SUPPLY HOSE IS NOT IN CONTACT WITH OR NEAR THE BURNER BOX Made in South Africa Pty Ltd...

Reviews: