6-2
NUMBER OF RED FLASHES
CAUSE
SOLUTION
1
Æ
Power Pack High Voltage
Reset charger (interrupt AC power for 15
seconds).
2
ÆÆ
Power Pack Low Voltage
Reset charger (interrupt AC power for 15
seconds).
3
ÆÆÆ
Charge Timeout caused by power
pack not reaching required voltage.
Charger output was reduced due to
high temperatures.
Check connections.
Operate charger at a lower ambient
temperature.
4
ÆÆÆÆ
Power pack could not be trickle
charged up to minimum voltage.
Contact CSC.
5
ÆÆÆÆÆ
Over-Temperature: Charger shut down
due to high internal temperature.
Ensure sufficient cooling air flow and reset
charger (interrupt AC power for 15 seconds).
6
ÆÆÆÆÆÆ
Charger Internal Fault
Reset charger (interrupt AC power for 15
seconds). Contact CSC if fault persists.