14 • Installation & Operation
INSTALLATION & OpERATION
The bottom of the end panels are protected by steel support plates, which must be unbolted and removed before the lineup is set. There are
bolts that go up through the support plates into the underside of the foamed floor.
A 1" wide trim piece is shipped inside the case to seal the vertical gap between cases being joined. It needs to be attached on the right of the
first case using the top and bottom joining holes in the extrusion. The next case in the lineup should slide up to the trim piece so that the door
seals against the trim piece.
A case must be prepared with Butyl caulk before setting the next case in the lineup. Case caulking instructions and caulk are shipped with every
case (
Move the next case into position and bolt it to the first case using the 4 joining bolts that are provided. Begin tightening the bolts at the top rear,
working down the back of the case and up the front, making sure that the seams are flush.
Do not pull cases together using joining bolts.
The interior case seams must be sealed using silicone sealant for NSF compliance (
and silicone sealant to contact one another as this may affect adhesion or color of each.
An insulated divider is used to join 2 different case models or 2 different temperature cases. The divider is typically factory-installed to one of the
cases. There are 2 types of insulated dividers:
1. Between a Crystal
™
cooler and a different case: The insulated divider has a panel on each side with nut inserts in the panels; each side is
bolted to the respective end frames.
Do not pull cases together using joining bolts.
2. Between 2 Crystal
™
coolers: The insulated divider uses a thru-bolt design. The divider is attached to one of the cases using short bolts for
shipping. When the cases are installed, the short bolts are removed and longer joining bolts are installed to bolt the cases together. Do not
pull cases together using joining bolts.
ultra Narrow Case Anchoring
The Ultra Narrow case (RVMC24UN) must be anchored to either another case or a wall to ensure the case will not tip forward.
The
Back-to-Back ultra Narrow (RVMC24BBuN) does not require anchoring. It may be used as the anchor for the ultra Narrow case.
Two case-to-wall support brackets will be provided when anchoring the ultra Narrow to a wall (
). Two case-to-case support
brackets will be provided when anchoring the ultra Narrow to another case. The ultra Narrow case must be set 3" away from the other case for
proper ventilation, so a provided trim piece must be field-installed to cover the gap (
3" TO 5"
FROM REAR
OF CASE
-
TO
-
WALL
5"-20" DIM
TO CENTER
5"-20" DIM
TO CENTER
SCREW (2) TIP OVER PREVENTION
BRA
C
KETS (ZZ #18-0422)
TO TOP OF CASE AND TO
A SOUND STRUCTURAL
SUPPORT MEMBER IN WALL
TIPOVER PREVENTION BRACKET
ZERO ZONE WORKMANSHIP STANDARDS SHALL APPLY PER
ES-08-1007
ASME Y14.41-2012 & ASME Y14.5-2009 SHALL APPLY AS REQUIRED
ALL DIMENSIONS IN INCH UNLESS OTHERWISE SPECIFIED
RELEASED
SIGNIFICANT DIMENSIONS DENOTED BY X.XX
OR X.XXX AND MUST MEET Cpk ≥ 1.33.
CRITICAL DIMENSIONS DENOTED BY X.XX
OR X.XXX
AND MUST MEET Cpk ≥ 1.66.
CAD DRAWING
NO MANUAL REVISIONS
COPYRIGHT INFORMATION
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN,
IS THE SOLE PROPERTY OF ZERO ZONE, INC. ANY USE OF
THIS DOCUMENT OR DISCLOSURE OF ITS CONTENTS; BY
REPRODUCTION OR OTHER MEANS, WITHOUT THE WRITTEN
CONSENT OF ZERO ZONE, INC. IS STRICTLY PROHIBITED.
FINISH:
MATERIAL:
NOT TO SCALE
SCALE:
MODELED BY:
DRAWN BY:
4/24/2018
A
1 OF 1
66-0078
MOUNTING INSTRUCTIONS FOR
SHEET:
DATE:
REVISION
ZERO ZONE, INC.
110 NORTH OAKRIDGE DRIVE
NORTH PRAIRIE, WISCONSIN
USA 53153
DRAWING No:
DESCRIPTION:
REVISION INFORMATION
A NEW ISSUE
12796
4/24/2018
AR
No. REVISION DESCRIPTION
ECN No.
DATE
BY
Al Roeker
Al Roeker
SHEET SIZE
A
TOLERANCES SHALL APPLY
UNLESS OTHERWISE SPECIFIED
.X = ± .1
.XX = ± .02
.XXX = ± .005 ANGLES, ± 1º
FIGURE 17: Anchoring Ultra Narrow to a Wall