4 • Installation & Operation
INSTALLATION & OPERATION
!
CAUTION!
DO NOT STAND ON TOP OF A REVEAL MERCHANDISER
®
. THE TOP OF THE CASE IS NOT DESIgNED TO
SuPPORT THE WEIgHT OF A PERSON.
Delivery Inspection
Zero Zone display cases are carefully factory-tested, inspected, and properly packed to ensure delivery in the best possible condition. The
equipment should be unwrapped and checked for damage immediately upon delivery. DAMAGE MUST BE NOTED AT TIME OF DELIVERY,
AND ALL CLAIMS FOR DAMAGES MUST BE FILED WITH THE TRANSPORTATION COMPANY, NOT WITH ZERO ZONE. The carrier will
supply necessary report and claim forms.
Do not leave, store, or hold case outdoors in direct sunlight or high ambient temperature. This could potentially cause any plastic
inside the case to deform or warp.
Packaging
IMPORTANT: The hand rail, canopy, and honeycomb holder are shipped with protective coating. Do not remove this coating until cases
are completely installed. Wooden supports are used for shipping cases without end panels. These can be removed after moving the
case into position.
Each case in a lineup is labeled to identify the lineup and joint
. The label uses a 2-digit number designation, separated by a decimal. The first
number indicates the case lineup. The second number indicates the case joint. Case joints begin with the number “1” at the left most joint in the
lineup when looking at the front of the lineup. The first case in the lineup will be labeled on the right end and the second case in the lineup will be
labeled on the left end. The numbers on each end to be joined will match (
The
first
case in a lineup (with the right side labeled “x.1”) has a packet attached to the shelving that contains touch-up paint. Every case in
a lineup has a packet attached to the shelving that contains important information about the case and/or lineup and, if applicable, special
instructions for installing ordered options.
Bumpers and kickplates are shipped on top of the case. Shelves for the case are tie-wrapped and blocked into the individual cases. Other
accessories like drain traps, drain pans, condensate evaporation pans, and hat channel rails are shipped in the case that require the parts.
Location
These cases must not be installed in the direct rays of the sun or near a source of radiant heat. Be certain that the floor under the installation is of
sufficient strength to prevent sagging. Uneven surfaces will result in reduced performance.
Cases should be set to allow a minimum 3" of space behind the back of the units. This will allow necessary air to circulate behind the display
cases and prevent condensation. Higher humidity stores with minimal air circulation require at least a 4" gap. A minimum 2" gap is recommended
between cases on end-to-end installations. All minimum spacing requirements may increase if seismic restraints are used.
Building soffits must be set back at least 6" from the front of the cases to allow access to electrical wiring on the top of the case.
INSTALLATION & OPERATION
Front of Back-to-Back Lineup
1.1B 1.1B
1.2B 1.2B
1.1A 1.1A
1.2A 1.2A
Front of Lineup
1.1 1.1
1.2 1.2
FIGURE 1: Case Label Information
Front of Lineup