Revision Date – 15/07/2020
page 49
10 SERVICE BY REFRIGERATION MECHANIC
10.1 Compressor recharge information
The ARB fridge freezer range as designated in this manual use refrigerant R134a.
Fridge Model
ZERO
36L
ZERO
44L
ZERO
60L
ZERO
69L DZ
ZERO
73L
ZERO
96L DZ
ZERO
105L
Fridge Type
10802010 10802020 10802030
10802040
10802050
10802060
10802070
Refrigerant
Type
R134a
Refrigerant
Quantity
43g
45g
65g
75g
70g
96g
100g
10.2 Leaks in the refrigerant system.
If low refrigerant is suspected, the system should be pressure tested.
If the pressure test identifies a leak, the location of the leak should be found.
To locate the leak, the refrigerant system should be split into two sections (see below) and pressure
tested separately.
Section 1 - All refrigerant lines and components external to the foamed cabinet. This includes the
compressor and condenser.
Section 2 - The evaporator and all refrigerant lines inside the foamed cabinet.
If the refrigerant leak is located externally of the evaporator and foamed cabinet, the leak may be
repaired. If the fridge is inside the warranty period a complete replacement is required.
If a refrigerant leak is detected inside the evaporator or foamed cabinet, the fridge should be replaced.