background image

Revision Date – 15/07/2020 

 

page 5  

4  SPARE PARTS 

4.1  Spare parts list 

The items in the following table correspond with the items on the exploded diagram in section 

4.2

. 

 

ITEM 

ARB MAIN DESCRIPTION 

QTY 

ARB PART # 

LID LATCH ZERO 36/44L 

1 kit 

10910142 

LID LATCH ZERO 60/69/73/105L 

1 kit 

10910143 

LID LATCH ZERO 96L 

1 kit 

10910144 

CABINET PIN HINGE ZERO 36/44L 

1 pair 

10910145 

CABINET PIN HINGE ZERO 60/69/73/96/105L 

1 pair 

10910146 

LID SOCKET HINGE ZERO 36/44L  

1 pair 

 

LID SOCKET HINGE ZERO 60/69/73/96/105L 

1 pair 

 

CONDENSER FAN ZERO 

10910159 

COMPRESSOR CONTROL UNIT ZERO 36/44L 

10910161 

10 

COMPRESSOR CONTROL UNIT ZERO 60/69/73/96/105L 

10910162 

11 

INTERIOR LIGHT LENSE ZERO 

10910171 

12 

CORNER COLUMN ZERO 36L 

1 kit 

10910172 

13 

CORNER COLUMN ZERO 44L 

1 kit 

10910173 

14 

CORNER COLUMN ZERO 60L 

1 kit 

10910174 

15 

CORNER COLUMN ZERO 69/73L 

1 kit 

10910175 

16 

CORNER COLUMN ZERO 96/105L 

1 kit 

10910176 

17 

LID RUBBER INSERT ZERO 36/44L 

10910177 

18 

LID RUBBER INSERT ZERO 60/69/73/96/105L 

10910178 

19 

HANDLE ASSEMBLY FRONT ZERO 60/69/73/96/105L 

1 kit 

10910179 

20 

HANDLE ASSEMBLY REAR ZERO 60/69/73/96/105L 

1 kit 

10910180 

21 

HANDLE ASSEMBLY FRONT ZERO 36/44L 

1 kit 

10910181 

22 

HANDLE ASSEMBLY REAR ZERO 36/44L 

1 kit 

10910182 

23 

HANDLE SUPPORT BRACKET ZERO 36/44L 

1 kit 

10910183 

24 

HANDLE SUPPORT BRACKET ZERO 60/69/73/96/105L 

1 kit 

10910184 

25 

RUBBER FOOT ZERO 

10910185 

26 

DRAIN PLUG 

10910186 

27 

LID ZERO 36/44L 

10910194 

28 

LID ZERO 60/69/73L 

10910195 

29 

LID ZERO 96LDZ 

10910196 

30 

LID ZERO 105L 

10910197 

31 

COMPRESSOR BASE SUPPORT ZERO 

10910202 

32 

VENT SHROUD SCREWS SIDE ZERO 

1 set 

10910204 

33 

VENT SHROUD ZERO 36/44L 

10910206 

34 

VENT SHROUD ZERO 60/69/73L 

10910207 

35 

VENT SHROUD ZERO 96/105L 

10910208 

36 

DISPLAY PANEL TOUCHPAD  

10910209 

37 

ARB BADGE LOGO ZERO 

10910210 

38 

POWER SOCKET SUPPORT PANEL 

1 kit 

10910211 

39 

COMPRESSOR BASE PLATE ZERO 36/44L 

10910216 

40 

COMPRESSOR BASE PLATE ZERO 60/69/73L 

10910217 

41 

COMPRESSOR BASE PLATE ZERO 96/105L 

10910218 

42 

BASKET SYSTEM ZERO 36L 

1 system 

10910187 

43 

BASKET SYSTEM ZERO 44L 

1 system 

10910188 

44 

BASKET SYSTEM ZERO 60L 

1 system 

10910189 

45 

BASKET SYSTEM ZERO 73L 

1 system 

10910190 

46 

BASKET SYSTEM ZERO 105L 

1 system 

10910191 

47 

BASKET SYSTEM ZERO 69LDZ 

1 system 

10910192 

48 

BASKET SYSTEM ZERO 96LDZ 

1 system 

10910193 

49 

POWER SOCKET SUPPORT PANEL REAR 

 

 

NOTES: 

  Quantity column indicates maximum number of individual items per service repair. 

  The part number given is for singular units unless otherwise stated in the item description. 

  Drawings are indicative only, product appearance may change slightly. 

Summary of Contents for ARB

Page 1: ...SERVICE MANUAL ZERO Single Zone Models 36L 38qrt 44L 46qrt 60L 63qrt 73L 77qrt 105L 111qrt Dual Zone Models 69L 73qrt 96L 101qrt...

Page 2: ...un on 100 240V AC power 20 7 2 Fridge will not run on 12 24V DC power 21 8 CHECKS AND TESTS 22 8 1 Vehicle wiring system 22 8 2 Test AC Rectifier 25 8 3 Test Compressor control unit 12 24V DC 28 8 4 T...

Page 3: ...working practices must be exercised while performing any work on an ARB Fridge Freezer 1 2 How to use this manual This manual has been developed as an electronic resource To navigate through this man...

Page 4: ...e eg scratches dents stain etc and documented on the application 2 Assess the fridge to identify the fault s 3 Complete a copy of the warranty claim form and forward it to your regional ARB Office To...

Page 5: ...red Light LED is only covered under warranty for the first 3 months after the initial purchase date ARB will not pay for the removal or replacement of a fridge freezer that has been built in unless au...

Page 6: ...MBLY REAR ZERO 36 44L 1 kit 10910182 23 HANDLE SUPPORT BRACKET ZERO 36 44L 1 kit 10910183 24 HANDLE SUPPORT BRACKET ZERO 60 69 73 96 105L 1 kit 10910184 25 RUBBER FOOT ZERO 1 10910185 26 DRAIN PLUG 1...

Page 7: ...Revision Date 15 07 2020 page 6 4 2 Spare parts exploded drawing The items in the following exploded diagram correspond with the items in the table in section 4 1...

Page 8: ...58 74 MAIN PCB ZERO DUAL ZONE 1 10910219 75 INTERIOR LIGHT PCB ZERO 1 10910170 76 DC SOCKET COVER ZERO 1 10910198 77 VENT SHROUD SCREWS BASE ZERO 1 10910205 78 FRIDGE BASE PLUG ZERO 1 10910212 79 THER...

Page 9: ...ble Short length of insulated wire terminated with spring loaded clips or push on connectors at each end The following tools will be required to perform specific non refrigeration based servicing of t...

Page 10: ...e freezer off because the fan is drawing more than 0 6 amp while the compressor is running This could be because the fan is running slowly or not running at all Check that the fan is not obstructed or...

Page 11: ...g is correct and that power is available at the outlet socket The DC supply voltage is below the minimum voltage needed to operate the fridge Connect the fridge to a 12 or 24V DC power supply Check th...

Page 12: ...if necessary refer to section 9 4 Faulty main circuit board Test compressor control unit refer to section 8 3 If control unit is ok test fridge with new main circuit board and replace if necessary re...

Page 13: ...voltage and voltage at supply socket NOTE Voltage readings must be taken with a load on the circuit to allow for voltage drop within the circuit refer to section 8 1 Check that plug is correctly inst...

Page 14: ...ed to the compressor control unit Check the fan wiring to ensure the ve and ve fan wires are correctly connected to the compressor control unit refer section 9 9 Faulty fan Test with new cooling fan r...

Page 15: ...electrician Faulty main circuit board Test with new main circuit board If symptom resolved replace circuit board refer to section 9 6 Faulty compressor control unit Test compressor control unit on AC...

Page 16: ...ssor and condenser If a leak is detected contact a qualified refrigeration mechanic for service advice If no leak detected contact a qualified refrigeration mechanic and request that the system is pre...

Page 17: ...ze with fridge set to warmest setting Faulty thermistor Test thermistor refer to section 8 4 and replace if necessary refer section 9 10 Faulty control panel circuit board Test fridge with new control...

Page 18: ...y main circuit board Test fridge with new main circuit board and replace if necessary refer to section 9 6 Insufficient charge of refrigerant in compressor system Contact a qualified refrigeration mec...

Page 19: ...customer that latch must be correctly closed before transportation Faulty latch Inspect latch and latch pivot for damage Lid will not open when fridge is running The air inside the fridge has cooled f...

Page 20: ...f voltage 12V DC 10 1 0 3 V 11 4 0 3 V 11 8 0 3 V Restart voltage 12V DC 11 1 0 3 V 12 2 0 3 V 12 6 0 3 V Switch off voltage 24V DC 21 5 0 3 V 22 5 0 3 V 23 0 0 3 V Restart voltage 24V DC 23 0 0 3 V 2...

Page 21: ...TO DC TESTING TEST COMPRESSOR CONTROL UNIT YES YES FRIDGE DOES NOT RUN Contact ARB for technical advise IS THE MAIN CIRCUIT BOARD FAULTY IS THE COMPRESSOR CONTROL UNIT FAULTY YES NO YES NO CHECK DEVIC...

Page 22: ...nic for assistance NOTE THIS IS EXTREMELY UNLIKELY RECONNECT CONTROL UNIT YES YES NO YES COMPRESSOR DOES NOT RUN Contact ARB for technical advice YES CHECK BATTERY PROTECTION SETTING CHECK VEHICLE WIR...

Page 23: ...some 12V vehicle wiring systems the voltage drop between the battery and the rear factory accessories socket can exceed 2V DC It is important that the vehicle is not running while these voltage readi...

Page 24: ...gnition is turned off NOTE ARB recommend that a dedicated wiring circuit be used to connect the fridge directly to the battery via a suitable fuse Refer to the wiring advice below Press the red button...

Page 25: ...he circuit should be connected directly to the negative terminal of the battery It should not be grounded directly to the vehicle body or chassis B Check that all terminals and joints are clean and in...

Page 26: ...40VAC Contact with these components may cause serious injury or death Please be very careful not to contact or touch any components other than described in this instruction Take a multimeter and set t...

Page 27: ...e compressor With the multimeter terminals insert the negative terminal into the black wire at the top Insert the positive terminal into the red wire second from the top The multimeter will display th...

Page 28: ...omprehensive check on all other potential causes the AC rectifier may be the cause and should be replaced The measured DC voltage is considerably less than the supply voltage A Remove the DC power sou...

Page 29: ...ads from the back of the fridge Remove the front cover refer to section 9 3 Identify the compressor control unit Disconnect the push on connectors from terminals T P and C Apply 12 or 24V DC to termin...

Page 30: ...refit the push on connectors to terminals C P and T NOTE During this test the compressor should draw approximately 3 amps or greater depending on the fridge model size NOTE There may be a delay of ap...

Page 31: ...istance between the two metal contacts in the plastic connector plug as shown NOTE The resistance of the thermistor will increase as the fridge gets colder Measure the temperature of the plastic liner...

Page 32: ...he internal temperature calibration should not be changed Procedure Connect the fridge to 12 24V DC or 100 240V AC Turn the fridge on Press and hold and simultaneously until A 0 appears on the display...

Page 33: ...ND REPAIR 9 1 Handles Replace With Allen key remove all six fasteners securing the handle assembly Remove the plastic handle assembly With Allen key remove all four fasteners securing the handle suppo...

Page 34: ...off the fridge and remove easily To refit corner columns To refit column align column on corner of fridge Hold firm in position and install the top fastener and tighten loosely Insert the remaining th...

Page 35: ...er as described in Section 9 2 Remove the side screws from the front cover There are three screws on each side of the front cover Remove the base screws from the front cover There are twelve 12 screws...

Page 36: ...the power supply panel Remove four screws and pull the power supply panel from the front cover To remove the touchpad panel first peel back the decal with thin blade This will allow access to four sc...

Page 37: ...for the touchpad and power supply Insert all wire terminals into their correct position Flip the front cover back over the fridge cabinet as shown Fasten the front cover to the body of the fridge usi...

Page 38: ...ing the front cover With thin blade remove the corners of the touchpad decal to gain access to the screws behind the decal With screw driver remove the four retaining screws from the touchpad support...

Page 39: ...terminals Remove two mounting screws securing the compressor control unit to the side of the compressor Pull the compressor control unit away from the compressor as per the arrow shown Remove the thr...

Page 40: ...9 3 Locate the main circuit board and disconnect all connectors from the main circuit board Remove the four retaining screws securing the main circuit board to the front cover The main circuit board...

Page 41: ...NET LIGHT THERMISTOR COMPRESSOR CONTROL UNIT FAN USB EMERGENCY OVERIDE SWITCH DC JUNCTION BOX COMPRESSOR CONTROL UNIT LIGHT FRONT THERMISTOR REAR DISPLAY PCB DC JUNCTION BOX COMPRESSOR CONTROL UNIT TH...

Page 42: ...e plate To do this you will need to hold the top securing nuts with a spanner It is recommended to the prop the compressor while doing this as the compressor is quite heavy and will damage other compo...

Page 43: ...age 42 With screw driver remove all remaining screws securing the base plate to the fridge cabinet and column The compressor base plate can now be removed To refit the new base reverse the process as...

Page 44: ...n Section 9 7 Pull out the AC Rectifier assembly to gain access to the assembly Remove the plastic cover by unscrewing the four retaining screws Remove the AC Rectifier PCB from the plastic housing by...

Page 45: ...d remove the wires connected to the AC power socket Disconnect and remove the wires connected to the Main PCB The AC Rectifier can now be removed from the fridge To refit the AC Rectifier reverse the...

Page 46: ...been confirmed Remove fan retaining screws that secure the fan to the condenser CAUTION Take care not to stretch the refrigeration lines or power cables Remove fan Install the new fan and fasten to th...

Page 47: ...zone fridges there are two thermistors The longer thermistor cable is for the rear zone and the shorter thermistor cable is for the front zone Single Zone main circuit board Thermistor Dual Zone main...

Page 48: ...nsert the thermistor wire until the mark made in the previous step lines up with the body of the fridge Secure the thermistor wire in place with the P clip screw and sealing compound Install the new t...

Page 49: ...G10A Reassemble the plug and test for continuity 9 12Device fuse 100 240V AC Replace Remove the AC and DC power leads from the power sockets Remove the fuse insert from the rear panel of the fridge as...

Page 50: ...e pressure tested If the pressure test identifies a leak the location of the leak should be found To locate the leak the refrigerant system should be split into two sections see below and pressure tes...

Page 51: ...Revision Date 15 07 2020 page 50 11 WIRING 11 1Wiring diagram Single Zone...

Page 52: ...Revision Date 15 07 2020 page 51 11 2Wiring diagram Dual Zone...

Reviews: