Problem

Procedure

Behavior

Procedure II

Door doesn’t 

work

Make sure you have 230V 

power supply connected 

to control board and if it 

is working properly.

Still not working.

Consult  a  qualified  ZERO 

technician.

Motor doesn’t 

move but makes 

noise

Unlock motor and move 

the gate by hand to check 

for mechani cal problems 

on the movement

Encountered problems?

Consult an experienced 

gate expert.

The gate moves easily?

Consult a qualified ZERO 

technician.

Motor opens 

but doesn’t

close

Unlock  motor  and  move 

the gate by hand to closed 

position.

Lock motor again and turn 

off power supply for 5 se

-

conds. Reconnect it and 

send start signal using 

transmitter.

Gate opened but didn’t clo

-

se again.

Check if there is any obsta

-

cle in front of the photo-

cells;

Check if any of the control

-

devices  (key  selector,  push 

button,  video  intercom, 

etc.)  of  the  gate  are  jam

-

med and sending perma-

nent signal to control unit;

Consult  a  qualified  ZERO 

technician.

Gate doesn’t 

make complete 

route

Unlock motor and move  

ate by hand to check for 

mechanical problems on 

the  gate

Encountered problems?

Consult an experienced 

gate expert. 

The gate moves easily?

Consult  a  qualified  ZERO 

technician.

05. TROUBLESHOOTING

Summary of Contents for Z02 Series

Page 1: ...zero HOME AUTOMATION Z02 SWING GATE PG1 USER MANUAL AND CONFIGURATION Z02 REV01 2018 IT EN FR zero HOME AUTOMATION Z02 SWING GATE MOTOR SUPPLY 230 24V...

Page 2: ...zero HOME AUTOMATION Z02 SWING GATE PG2 zero HOME AUTOMATION...

Page 3: ...RO SRLS is not responsible for the improper use of the product or other use than that for which it was designed ZERO SRLS is not responsible if safety standards were not taken into account when instal...

Page 4: ...re the following Z02 400 Z02 400 24 Z02 600 Z02 600 24 Power Supply 230Vac 50 60Hz 24Vdc 230Vac 50 60Hz 24Vdc Power 180W 60W 180W 60W Current 1 4 A 1 3 A 1 4 A 1 3 A Capacitor 8 F 8 F RPM 1400 Noise l...

Page 5: ...from the floor to the top of the rear support Dimension B Vertical distance from the floor to the top of the front support Example Set dimension A this can be any size of your choice After you set di...

Page 6: ...ening mechanical stopper On the Illustrated diagrams below and are the dimensions for the installation of the automated system Opening mechanical stopper Opening direction EXTERIOR Axis of rotation of...

Page 7: ...r support must be fixed to the pillar or wall using dimensions provided in the preceding pages It can be fixed using screws with mechani cal bushing or chemical welding process or one of your choice s...

Page 8: ...rlier on each place with a small amount of lubricant for less friction Move the door manually to see if the door opens and closes uniformly and cor rectly without any irregular friction during its ent...

Page 9: ...nt to use mechanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will be...

Page 10: ...omogeneous layer of lubricant over the arm Lubricate pins Remove front and rear caps Place a small amount of lubricant on the holes that contains support pins Install caps on the respective holders 04...

Page 11: ...SWING GATE PG11 02 Insert Release key on the unlock shaft 03 Rotate key 180 in the direction indi cated in the figure to unlock NOTE To lock operator so it can work automatically must do it by turnin...

Page 12: ...n t close Unlock motor and move the gate by hand to closed position Lock motor again and turn off power supply for 5 se conds Reconnect it and send start signal using transmitter Gate opened but didn...

Page 13: ...ere is some security systems malfunction photocells safety edges etc 1 Close with a shunt all safety systems on the control board check manual of the control board in question If the automated system...

Page 14: ...____________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _______...

Page 15: ...zero HOME AUTOMATION Z02 SWING GATE PG15 zero HOME AUTOMATION...

Page 16: ...zero HOME AUTOMATION Z02 SWING GATE PG16 zero HOME AUTOMATION ZERO SRLS Via ROMA 25 A ALTAVILLA VIC ITALIA info miozero it www miozero it...

Reviews: