INSTALLATION DIMENSIONS
Z02 specifications are as follow: The operator Z02 must be installed with a small inclination , to
prevent water infiltration through the extension arm.
For this, the front support must be fixed to the gate with a height lower than the height of the
rear support. See example below:
Dimension A • Vertical distance from the floor to the top of the rear support .
Dimension B • Vertical distance from the floor to the top of the front support.
Example:
• Set dimension A (this can be any size of your choice).
• After you set dimension A, subtract 10mm to find dimension B.
• If the height of the rear bracket (dimension A)is set at 600 mm, then the height of the front
bracket (dimension B) will be 590 mm (600mm-10mm).
It is very important that these dimensions are respected! Only this way can be
as- sured the correct functioning and durability of the operators!
It is also very important to have a levelled ground/terrain!