INSTRUCTION MANUAL
Rev. A
Dongguan Zerun Electronics Technology Co.,Ltd.
( NO.1 Xianxi Industrial Park, Zhen‘an Road, Shangjiao, Chang’an Dongguan, Guangdon, P.R. China )
7 / 9
Panel Mounting
Install on a flat, vertical housing surface which thickness of the housing wall not less than 1.5mm.
The diameter of the through-hole on the panel shall be between 12.9 mm and 13mm
The surface of the through-hole where match with o-ring shall be smooth, and there
shall be no burrs or other defects which might scrape the o-ring.
Insert the connector through the hole on panel, and then install the gasket and nut. See Picture 14.
During the process Zerun wrench can be used. See Picture 15.
Recommended torque of installing nut is 2 N.m.
Insert contact cable assembly into back of male and female connector. A “click” should be heard or felt
when the contact cable assembly is seated in correct position. Contacts cannot be removed once
seated. See picture 16.
Picture 14
INSERT
GASKET
NUT
HOUSING WALL
Picture 15
WRENCH