REF #0907-53
TEMPERATURE CONTROLLER:
NOTE
:
* DON’T TOUCH THESE ADJUSTMENTS, IT’S ALREADY CALIBRATED
#VD 2001 / 2601 INITIAL POWER-UP:
) When power is applied to the
control it will begin operating using the factory set point. The process temperature as measured by
the thermocouple will appear in the digital display and the
LOAD (PV)
will indicate if the control
output (load) is on.
Key-pad:
- Parameter display / set-point programming.
-Press toRaiseTemperature of Oven.
-Press toLower Temperature of Oven.
WARNING:
To program Controller follow the following steps:(adjustments to be done only by qualified technicien)
1) Press and hold
for 5 seconds till
appears, then keep pressing togling
till
appears. Press
till you find 0 100 this unlocks the program.
2) Press
till
appears press
or
till you find 0.0.
3) Press
till
appears press
or
till you find 2.
4) Press
till
appears press
or
till you find 0.
5) Press and hold
for 5 seconds till
appears, then keep pressing togling
till
appears press
or
till you find (K thermocouple)
6) Press
till
appears press
or
till you find Fº or Cº
7) Press
till
appears press
or
till you find 0000.
8) Press
till
appears press
or
till you find
9) Press
till
appears press
or
till you find 0.
10) Press
till
appears press
or
till you find 625Fº or 330Cº.
11) Press
till
appears press
or
till you find 5.0.
12) Press
and
holding both to exit program.
13) Press and hold
for 5 seconds till
appears,
then keep pressing togling
till
appears. Press
or
till you find 0 001
this locks the program.
14) Press
and
holding both to exit program.
#11 Input Power
#12 Output to
selenoid or SSR
#13 110v black
#14 110v white
#6 Thermocouple
negative
#7 Thermocouple
positive
WIRING CONNECTION