PREMIER EVACS 1-16 INSTRUCTION MANUAL: 2-ZONE NETWORKED VOICE ALARM PANEL
Document no: GLT-237-7-1
PAGE 9
Issue: 1.5
Date: 02/04/2014
Mounting the voice evacuation panel
The Premier EVACS 1-16 comes with many cable entry holes. If another entry hole is required, it is strongly
recommended that the panel door is removed to avoid accidental damage. Also the PCB assemblies should be
removed and stored in a safe place. This would also help while fixing the back box to the wall.
Planning cable entry
The figure below shows the location of the cable entries to facilitate planning of wiring to be brought to the panel.
If a cable-entry push-out is removed, fill the hole with a brass cable gland. If any knockout is removed, but
subsequently not used, it should be covered up using a 20mm blanking grommet.
The 230V AC Mains cable must be fed into the enclosure via one
of the cable entries at the top right corner of the back box. This
cable must be connected to the mains terminals of the power
supply, which are marked L, N, (Live, Neutral, Earth)
Take care not to damage the VACIE during installation.