Gas Sense Detectors

The 

Zeta Gas Sense

 detector is a 24V gas 

detector that can run either in stand alone 

mode, or can be connected to a control panel 

for the centralized monitoring of several 

detectors.

Stand Alone Mode

In stand alone mode, the detector has 3 relay outputs, 

and a monitored 24V output (Intended for alarm sirens). 

The 3 relay outputs correspond to the 3 alarm levels 

of 

PREALARM

ALARM 1

 and 

ALARM 2

. Each of these 

threshold levels has a default setting, and can be 

altered by +/- 5% or +/- 10%.

The detector will display the gas type, the current 

status (normal, fault or alarm), along with the current 

sensor reading on its 2 x 16 character LCD display. As 

the gas concentration level rises, the detector will light 

its relevant alarm LEDs and operate its relays. They 

operate concurrently, so that in the highest alarm level, 

all lower alarm LEDs & relays will remain ON.

System Mode

In System mode, the detector will display 

SYS

 to 

indicate that it is now part of a system. It will function 

similar to when it is in Stand alone mode, 

except

 the 

alarm relays will be under the control of the fire panel.     

This feature allows the control panel to monitor the 

system as a whole before deciding whether or not to 

operate an output. 

The detectors can also be locally recalibrated, with 

menu options to set the zero level, and options to set 

the calibration span, with the use of a calibration gas 

cylinder filled with the full scale gas concentration 

level.

At the end of the recommended working life of the 

sensor, a replacement sensor should be fitted. The part 

numbers for each sensor are shown on the specification 

table.

7

Summary of Contents for ZS-H2S/500

Page 1: ...Gas Sense Gas Detection System...

Page 2: ...s Detector 4 When to Test the Detector 5 Detector Construction 6 Gas Sense Detectors 7 Toxic Detector Specifications 8 Combustible Detector Specification 9 10 Zeta Sense Gas Control Panel 11 Zeta Addr...

Page 3: ...build up of combustible gas caused by a leak can cause an explosion Or a build up of toxic gas such as carbon monoxide can be fatal Introduction to the Gas Sense System With this in mind Zeta Alarm S...

Page 4: ...es under pressure it may be forced past the sensor rather than into it if the detector is too close Lighter Gases 30cm to 50cm Heavier Gases 30cm to 50cm Gases of Similar Weight to Air 1 2 to 2 0m Env...

Page 5: ...sing the instrument to a known concentration of test gas The instrument reading is compared to the actual quantity of gas present as indicated on the cylinder If the instrument s response is within an...

Page 6: ...dant ABS The filter housing is made from stainless steel The detector itself has 4 control buttons to allow configuration of the unit It has a 2 x 16 character LCD display plus 4 indication LEDS to sh...

Page 7: ...ll light its relevant alarm LEDs and operate its relays They operate concurrently so that in the highest alarm level all lower alarm LEDs relays will remain ON System Mode In System mode the detector...

Page 8: ...040ppm 050ppm 060ppm 070ppm 080ppm 020ppm 025ppm 030ppm 035ppm 040ppm 0 20kppm 0 25kppm 0 30kppm 0 35kppm 0 40kppm 020ppm 025ppm 030ppm 035ppm 040ppm 4 0ppm 5 0ppm 6 0ppm 7 0ppm 8 0ppm 060ppm 075ppm 0...

Page 9: ...ld Default 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 1st Alarm LEL Bold Default 20 25 30 35 40 20 25 30 35...

Page 10: ...0 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 10 15 20 25 30 1st Alarm LEL Bold Default 20 25 30 35 40 20 25 30 35 40 20 25 30 35 40 20 25 30 35 40 20 25 30 35 40 20 25 30 35 40 20 25 30...

Page 11: ...ility is useful if there are many detectors spread across a wide area on the system The system can be divided into 20 zones allowing detectors to be grouped either by gas type or by building area The...

Page 12: ...low the outputs to be programmed whilst others will have a default pre programmed operation Model ZIOU ZIOU 230 Part No 48 105 48 106 Operating Voltage 17 33V DC 17 33V DC Quiescent Current 900uA 900u...

Page 13: ...evice address and sound output of 94 dBA at 1m Both units have a built in short circuit isolator to provide system integrity in the event of cable damage Model ZAMT R ZAMT W ZAMTF R Part No 42 007 42...

Page 14: ...Typical Connection Diagram Zeta Maxitone Sounder ZIOU Zeta Addressable Gas Sense ZSC100 Single Loop Gas Control Panel 24V PSU Mains In 14...

Page 15: ...ated on the cylinder Within the specified tolerance range If a detector fails this bump test then it should be zero s in clean air then recalibrated using the calibration cap and the gas cylinder Test...

Page 16: ...Tel 44 0 1792 455 175 Fax 44 0 1792 455 176 E mail info zetaalarmsystems com Web www zetaalarmsystems com Detection House 72 78 Morfa Road Swansea SA1 2EN United Kingdom Available now from...

Reviews: