INFINITY ID2 INSTALLATION MANUAL.
Software Versions: PANEL 1.N & LOOP O.N
Approved Document No: GLT-211-7-1
Issue 1.9 Author: MG/NJ Date: 06/04/2016
PAGE 44
Installation Manual Modification History
ISSUE
DATE
CHANGES
1.0
22/1/2013
Initial Release (Section 16.5 coloured white (“deleted”) – waiting software update)
1.1
23/3/1013
Corrected enclosure dimensions // Added max loop length // Added SndSmoke and SndHeat to device
list // Added I/O Panel Link Information // Updated software version in header
Re-write section 16.5 (viewing test mode during alarm)
Deleted “Do not print…” from mod history page. This page will now be included as part of the manual
Added note that factory reset does not clear name. It must be manually deleted.
1.2
11/7/2013
Corrected Typos:-
Page 17. 11.1: 2
nd
line of table reads “AUX 28V 1” should read “AUX 28V +”
Page 32. 19.7: resetting from a system fault by use of the keyswitch. ID2 does not have a keyswitch.
Page 35. 22.2: In table: “|Battery deep discharge protection | batteries less than |” should read
“batteries less than 21V”
Deleted repeated “to teach” in Using this manual section
Added missing “HOLD” in handling PCB section
Corrected charge current from 150 to 350mA
Correct AUX power use in termination connections table.
Reworded :-
Changed "add ZIOU to loop" to "add I/O relay to detector circuits"
Reworded Topology description in menu structure table
Amended device fault description in general fault finding section
Deleted "loop on LED reference" in fault finding section - applies only to simplicity.
Updated:-
Changed BS5839 -1 references to 2013 version (4 occurrences)
Added loop wiring terminal information.
Added info to Electrical Spec: Max sounders / Max loop -zone current / Aux 28V voltage & current
Changed number of repeaters that can be powered from panel from 3 to 2.
Max & Min ratings in Electrical Specifications table.
1.3
8/7/2014
Corrected Charger current to 350mA. // Added addr detector wiring & addressing. // Corrected Max
Battery size to 7.2Ah // Corrected wrong mention of Simplicity Panel // Corrected mention of access key
Added missing “delete” in RESTORING THE PANELS DEFAULT SETTINGS section
1.4
8/7/2014
Changed “configure zone” section to reflect new menu layout // Changed “menu structure chart”
Added Resound configuration info // Changed fire screen info.
Added sounder fault / disablement message information
1.5
16/3/2015
Updated Enclosure drawings.
Changed addressing table so that switch numbers shown from 1 to 8 (Was in binary format from 7 to 1 ).
Added info about addressing App. // Changed max loop length from theoretical 2500 to 2000m
Deleted ID2 Base configuration info. // Corrected I/O Input Configuration.
Updated Verification info to include the new zonal verification option.
1.6
07/09/2015
Updated enclosure dimensions in spec table // Added missing supply fault finding information
1.7
11/12/2015
Updated Imax & I min info to show values as seen at CIE Output
1.8
14/1/2016
Updated rating table to show max, min & nominal values. Added PSU switching frequency & Maximum
ripple. Updated header to show latest F/W version.
1.9
6/4/2016
Corrected Max Battery size to 7Ah
Added battery type (section 6.2.5)
Corrected typo in ripple voltage 700mA -> 700mV
Corrected EN54 references (Dates & revisions)
Added Fuse rating table