97
ELECTRO-HYDRAULIC SYSTEM
F -02 -173
INDICATION OF EHR-B ERRORS
The electronic part of the electro-
hydraulic system continuously checks
proper functioning of the system. Possi-
ble errors are indicated by repeated
flashing combinations of the diagnostic
LED (7).
After the remedy of the error the diag-
nostic LED (7) goes off.
Permanent illumination of the diagnostic
LED (7) indicates the state of blocking of
the electro-hydraulic system.
DESCRIPTION OF SIGNALS OF EHR-B ELECTRO-HYDRAULIC SYSTEM
ERRORS
Flashing combination
of the diagnostic LED
(7).
Long pause
No. of flashes
Short pause
No. of flashes
Error category
Error description
1x
1x
1x
2x
1x
3x
1x
4x
1x
5x
1x
6x
Serious error
Error with internal safety shutdown of the
electro-hydraulic system - the electro-
hydraulic system is out of operation - the
work with the tractor must be stopped
2x
2x
2x
3x
2x
4x
2x
8x
Moderately se-
rious error
Error with internal safety shutdown of the
electro-hydraulic system - the electro-
hydraulic system is out of operation
3x
1x
3x
2x
3x 4x
3x 6x
Minor error
The electro-hydraulic system works with a
limitation resulting from the error type
Have EHR-B errors repaired by a specialized work-
shop.
Summary of Contents for FORTERRA 105
Page 1: ......
Page 2: ......
Page 7: ...7 LOCATION OF SERIAL NUMBERS XH154...
Page 32: ...32 ACQUAINTANCE WITH THE TRACTOR B21a...
Page 34: ...34 ACQUAINTANCE WITH THE TRACTOR F54b...
Page 46: ...46 NOTES...
Page 64: ...64 NOTES...
Page 68: ...68 NOTES...
Page 80: ...80 NOTES...
Page 106: ...106 NOTES...
Page 120: ...120 NOTES...
Page 130: ...130 NOTES...
Page 176: ...176 NOTES...
Page 190: ...190 NOTES...
Page 197: ......