Almost all the following works require certain experience and more exacting service and
diagnostic equipment. That's why we recommend to do the works at specialized or authorized
workshops.
Flat belt drive tension of accessories
Stretching the V-
belt in the Air-conditioner compressor
Stretching th
e V-belt in the compressor
It is not necessary to adjust the tightness of the flat
accessories-drive belt (A). The belt gets stretched
automatically.
NM14D002
If V-belt tightness (B) is appropriate, the belt sagging must
be 5.5 mm while a force of 50 N is acting on the belt.
Stretch tight the V-belt according to the prescribed value
after having loosened the fixing bolts on the air-conditioner
compressor.
NM14D003
If V-belt tightness (C) is appropriate, the belt sagging must
be 5.5 mm while a force of 50 N is acting on the belt.
Stretch tight the V-belt according to the prescribed value
after having loosened the fixing bolts on the belt tension
roller of the compressor.
NM14D004
ADJUSTMENT
117