background image

11

If mounting the CellPhone Detector Plus to drywall, plastic
anchors should be used. Press the plastic anchors into the
holes until fully seated. Turn each screw until the anchor is
tightly expanded. Leave the screw head exposed about

1

4

 inch (6.35 mm) for mounting.

ACTIVATION

After installing batteries in your CellPhone Detector Plus or if
an external power supply is to be used, remove the trim panel
on the front and make the following adjustments. See the
diagram on page 3 for switch locations. See “Battery
Replacement” on page 13 for instructions on installing the
batteries.

1. Move the POWER OFF/ON switch to the ON position.

2. Move the VOICE I/O DIP switch to the UP position to

enable the voice alarm message or to the DOWN position
for a beeps-only alarm. This is the left-most switch on the
DIP switch located above the ON/OFF switch.

3. Adjust the threshold setting with a small screwdriver. This

is factory-set to an intermediate distance.

Note

Unwanted alarms may indicate that the threshold
adjustment should be moved closer to NEAR. This will
prevent transmitters outside of the intended coverage
area from activating the alarm.

4. To set the alarm volume, press the TEST/MUTE button

and listen to the alarm. While the alarm plays, adjust the
VOL LOW/HI control to a satisfactory level using a small
screwdriver.

5. Other adjustments that can be made are Speaker Audio,

Flashing Light, and Auto-Registration Mode. These are
discussed in more detail in ”Features and Controls” on

Summary of Contents for CellPhone Detector Plus

Page 1: ...allowed for work performed by the buyer Equipment found to be not defective shall be returned at buyer s expense and testing and handling expense shall be borne by the buyer Out of warranty repairs w...

Page 2: ...ges into other areas This guide provides detailed information about the CellPhone Detector Plus For best operation please carefully read all the information in this guide prior to using or installing...

Page 3: ...a small control room hospital room or meeting room place the CellPhone Detector Plus close to the sensitive equipment but away from outside windows Set the threshold to MEDIUM Sensitive Equipment If a...

Page 4: ...pieces of equipment place an additional CellPhone Detector Plus in the hallway leading to the area Set the threshold to NEAR FEATURES CONTROLS The features and controls you need to be familiar with ar...

Page 5: ...g functions VOICE I O UP The alarm is a series of beeps followed by a voice message This is useful when self enforcement is desired DOWN The alarm consists of beeps only Useful to alert facilities per...

Page 6: ...signals See Auto Registration on page 9 for more details on the operation of this function DOWN The Auto Registration mode is not activated and short duration transmissions are ignored 4 SENSITIVITY A...

Page 7: ...e volume setting During an alarm pressing this button puts the CellPhone Detector Plus into an audio alarm mute mode that lasts for 90 seconds Pressing this button while the CellPhone Detector Plus is...

Page 8: ...is the front panel flashing light The Mute Mode lasts for about 90 seconds but can be canceled by simply pressing the TEST MUTE button OUTPUTS The CellPhone Detector Plus has two outputs audio and al...

Page 9: ...lus checks to see if an RF signal is still present If no RF signal is present the alarm output returns to the high impedance state This allows the alarm output to be used as a trigger to count the num...

Page 10: ...phone is ON For analog cellular phones these Auto Registration signals occur about every 30 minutes and last for only about 125 ms When a cellular phone is turned on it checks an internal counter to...

Page 11: ...your application then it may also be desirable to turn off the Flashing LED on the front of the unit and use the remote Alarm Output For more information about placement see TYPICAL APPLICATIONS on p...

Page 12: ...e VOICE I O DIP switch to the UP position to enable the voice alarm message or to the DOWN position for a beeps only alarm This is the left most switch on the DIP switch located above the ON OFF switc...

Page 13: ...w Battery Conditions When the charge in the batteries is low the CellPhone Detector Plus will sound a low battery alert consisting of single brief beep or tone approximately every 6 minutes Once the l...

Page 14: ...wall lift it up then away 3 Locate the four back cover screws and remove them 4 Remove the back cover and replace the four batteries according to the polarity diagram in the battery case 5 Re secure t...

Page 15: ...ency Response 400 2000 MHz optimized for 810 1950 MHz Detection Distance 2 17 m minimum line of sight user adjustable 20 30 m typical Alarm Message Pre recorded at factory English is standard Other la...

Page 16: ...icient power Replace the batteries or use an external DC power source The CellPhone Detector Plus is alarming to transmissions outside the intended coverage area The sensitivity is set too high Turn t...

Page 17: ...gle beep about every 6 minutes Batteries are low and need replacement My cellular phone is on but the CellPhone Detector Plus is not alarming The CellPhone Detector Plus only alarms when a cellular ph...

Page 18: ......

Reviews: