Hardware installation
16
Fig. 22
When the leveling is done, move the scanner unit manhandled from the outer left to the
outer right position and check if it does not touch the glass plate in any position.
Fix the 4 lock nuts (Fig. 13, [21]) at the scanner base and the two fixing screws on the
book cradle (Fig. 14 and Fig. 15 [23]).
Move the scanner unit manhandled back to the home position to make sure it does not
touch anything.
Remove the spacers from the glass plate.