Hardware installation
34
2.11
Cable connections for the scanner system
For the operation of the scanner system, you have to make the following cable
connections:
Connect the control and power cables at the scanner unit:
Connection
Connector
From
To
control 1 [80]
14 pin round
OS 11000 control unit
scanner unit
control 2 [81]
14 pin round
OS 11000 control unit
scanner unit
Firewire [82]
6 pin Firewire
scanner PC
scanner unit
AC Power [83]
3 pin power socket
OS 11000 control unit
scanner unit
Fig. 54
Switch on the power switch [84]. This switch can normally stay in ‘on’ position except for
service purposes.
The scanner PC should have at least the following configuration:
CPU
Interface/ Connector
Memory
(RAM)
Video Card
Min. Resolution
Pentium IV /
AMD Athlon >1GHz
(> 2GHz recommended)
Firewire 6pin
(included with the
scanner)
512MB
(1GB recommended)
16MB
1024x768 24bit