Hardware installation
39
Fig. 63
Connect the two air hoses [96] to the air compressor. One goes to the camera pneumatic
unit, the second one goes to the book cradle. The hoses will snap in and lock
automatically when pressing them towards the air socket [97].
Fig. 64
Connect the power cable of the compressor [98] to the multi-plug power socket [99]
delivered with the OS 11000. Turn the power switch [100] into the ‘1’ position. the
compressor will start pumping air into the air tank.
After a few minutes the air tank should be filled with air. Adjust now the pressure level of
the compressor at the regulator valve [101] to
5.5 bars
. If there is no pressure, check if the
air valve [102] is open. You can see the output pressure at the manometer [103]
.
96
96
97
100
101
102
103
Summary of Contents for OS 11000 Hybrid Color
Page 4: ...Preparations 4 Fig 2 Fig 3 Fig 4 3 4 5 6 8 7 9 10 11...
Page 7: ...Hardware installation 7 Fig 7 Fig 8 14 15...
Page 8: ...Hardware installation 8 Fig 9 Fig 10 16...
Page 10: ...Hardware installation 10 Fig 12 Fig 13 19 20 21 45mm...
Page 15: ...Hardware installation 15 Fig 20 Fig 21 29 29 30 29 29...
Page 19: ...Hardware installation 19 Fig 27 Fig 28 35 35...
Page 51: ...Software installation 51 Fig 84 4 Click on Finish to complete the installation Fig 85...