Installation and Operating Instructions V04 26
5.5.2 Assembling the DC connectors
Assemble the DC connectors as described below. Be sure to observe the correct
polarity. The DC connectors are marked with the symbols "+" and " − ".
Cable requirements:
The cable must be of type PV1-F, UL-ZKLA or USE2 and comply with the following
properties:
External diameter: 5 mm to 8 mm
Conductor cross-section: 2.5 mm² to 6 mm²
Qty single wires: minimum7
Nominal voltage: minimum 600V
Proceed as follows to assemble each DC connector:
1.
Strip 12 mm off the cable insulation.
Danger to life due to high voltages on DC conductors
When exposed to sunlight, the PV array generates dangerous DC voltage which
is present in the DC conductors. Touching the DC conductors can lead to lethal
electric shocks.
• Cover the PV modules with apaque material.
• Do not touch the DC conductors.