49 Installation and Operating Instructions V04
9.1.2 Control button
The inverter has a control button which is necessary to switch between the various
displays for measured values and device information, to enter next entry and to lock
the expected item.
The display menus wrap around, which means that when you arrive at the last item,
the first itemwill be displayed when you press the control button again.
You can freeze the display as follows:
Keep pressing the button for 5s whenthe display shows thedesireditem, and do not
release the button until you see ‛LOCK“. The display will always show the selected
item until you press the button again or the operating state of the inverter changes.
To save power, the backlight of the display turns off automatically after 10s. Press the
button again to activate it.
9.1.3 LEDindicators
The inverter is equipped with three LED indicators ‛green“, ‛red“ and ‛yellow“ which
provide information about the various operating states.
Green LED:
The green LED is lit when the inverter is operating normally.
Yellow LED:
The yellow LED flashes during communication.
Also, the yellow LED is lit during updatingfirmwarethrough RS485.
Red LED:
The red LED is lit when the inverter has stopped feeding power into the grid due to a
fault. The corresponding error code will be shown on the display.