3.7.3
Gearbox oil pump (option)
3.7.3.1
Specifications
Supply volume 3.4 dm
3
/ min.
Electrics:
Nominal voltage:
400V 50 Hz
Nominal rating:
100W
Operating mode:
S1 = 100% ED
Protection category:
IP 44
Nominal speed:
2 850 revs/min
Insulation class:
F
Thermal protection contact: 160°C when integrated and executed
Cable length:
approx. 1 000 mm
Hydraulics:
Supply volume:
1.21 cm³/U
Nominal pressure:
> 6.5 bar
Intake filter:
Filter mesh: 100
µ
m
Option:
Tank with larger volume (19 Ltr.)
The plastic container on the pump must be
removed when the tank is used. The pump is
then inserted together with the O-ring in the
appropriate opening and secured by means
of M8x35 cap screws.
More information about the products and func-
tional descriptions can be found in the operating
instructions
4161 758 005 (German)
4161 758 105 (English)