SET UP
Page5-21
5-6.4.2.2 Function Code C6 – ZF-Hurth Duty Cycle Ahead
5-6.4.2.3 Function Code C7 – ZF-Hurth Duty Cycle Astern
Figure 5-42: Display LED Function C6 Set Up
Activated
This function adjusts the maximum current available
to the Ahead Proportional Solenoid. Failure to limit
the current may result in permanent damage to the
solenoid.
The available Values are
00.0
to
100.0
percent Duty
Cycle of the applied voltage.
The Default Value is
100
%.
To determine, and if required, change the Value
(Refer to Sections 5-2 and 5-3, page 5-5):
A) Ensure that Troll is not selected (no rapidly
blinking LED).
B) Connect an amp meter in series with the Ahead
solenoid signal.
C) Move the Control Head lever to the Ahead
detent.
D) Scroll to Function Code
C6
.
E) Activate Set Up Mode.
F) Scroll Up or Down until the appropriate maxi-
mum current level is reached.
G) Store the Value to memory.
H) Return the Control Head lever to the Neutral/
Idle position.
Figure 5-43: Display LED Function C7 Set Up
Activated
This function limits the amount of current delivered
to the Astern Proportional Solenoid. Failure to limit
the current may result in permanent damage to the
solenoid.
The available Values are
00.0
to
100.0
percent Duty
Cycle of the applied voltage.
The Default Value is
100
%.
To determine, and if required, change the Value
(Refer to Sections 5-2 and 5-3, page 5-5):
A) Ensure that Troll is not selected (no rapidly
blinking LED).
B) Connect an amp meter in series with the
Astern solenoid signal.
C) Move the Control Head lever to the Astern
detent.
D) Scroll to Function Code
C7
.
E) Activate Set Up Mode.
F) Scroll Up or Down until the appropriate mini-
mum current level is reached.
G) Store the Value to memory.
H) Return the Control Head lever to the Neutral/
Idle position.
Function Code is Blinking
Summary of Contents for ClearCommand 9000 Series
Page 132: ......
Page 133: ...APPENDIX A...
Page 134: ......
Page 139: ......
Page 140: ...Page A 4...
Page 143: ......
Page 144: ...10...
Page 148: ...Page A 18...
Page 149: ...Page A 19 TEMPLATE...
Page 150: ...Page A 20...
Page 152: ...Page A 22...
Page 154: ...Page A 24...
Page 156: ...Page A 26...
Page 157: ...Page A 27 Drawing 11488D 1 Twin Screw Single APS Connection Alternate Remote Switch...
Page 158: ...Page A 28...
Page 159: ...Page A 29 Drawing 11488D 2 Twin Screw Dual APS Connections...
Page 160: ...Page A 30...
Page 161: ...Page A 31 Drawing 11488D 3 APS Notes Page...
Page 162: ...Page A 32...
Page 164: ...Page A 34...
Page 166: ...Page A 36...
Page 170: ...Page A 40...
Page 172: ...Page A 42...
Page 176: ...Page A 46...
Page 178: ...Page C 48 ZF Mathers LLC 12125 Harbour Reach Drive Suite B Mukilteo WA 98275...
Page 179: ...APPENDIX B...
Page 180: ......
Page 234: ...Appendix B 6...
Page 238: ...Appendix B 10...
Page 242: ...Appendix B 14...
Page 247: ...Service Field Test Unit Reference Manual MM13927 Rev E 4 07...
Page 248: ......
Page 250: ...Page ii Table of Contents...
Page 264: ...SERVICE FIELD TEST UNIT MM13927 RvD 10 03 Page 3 2...
Page 265: ...APPENDIX C...
Page 266: ......
Page 267: ...Appendix C 1 Drawing 12284A 1 ClearCommand Diagram all options...
Page 268: ...Appendix C 2...
Page 269: ...Appendix C 3 Drawing 12284A 2 ClearCommand Circuit Board Connections...
Page 270: ...Appendix C 4...
Page 271: ...Appendix C 5 Drawing 12284A 3 ClearCommand Drawing Notes Page...
Page 272: ...Appendix C 6...