10.3 Fire present
After the fumes temperature has reached and overcome the value contained in the parameter PR13, the
system goes into power mode displaying "
FLAME LIGHT" on the display and the LED ON/OFF flashes. In
this phase, it is checked that the temperature remains stable for a predefined time given by parameter PR02.
The fumes speed is given by the parameter PR17, the auger will turn on for a time given by the parameter
PR05 (auger LED intermittent) and
the ignition is switched off
(figure
5)
. Any anomalies will stop the
board and this will report the error
state. (Refer to chapter 12)
Figure 5
10.4 Stove on working mode
After the fumes temperature has reached and overcome the value contained in PR13 and maintained it for
at least a time PR02, the stove goes into working mode which is the normal operating. The display will show
the word "Work" and the LED ON/OFF is on. The power can be set by holding down the P2 button and the
room temperature can be set by pressing the P1 button (
Figure 6
). If the fumes temperature reaches the
threshold set by parameter PR15, the air exchanger fan lights up. (led exchanger on).
Figure 6
During this phase, after a time given by the parameter PR03, the stove carries out a cleaning of the brazier.
The message "
CLEANING FIRE-POT" will pass on the display, the auger is turned on (auger LED on) with a
speed given by the parameter PR09, the smoke extractor speed given by parameter PR08. (
Figure 6a
) Once
the given time by the parameter
PR12 has passed, the stove backs
in working state.
Figure 6a
FLAME LIGHT
work
CLEANING FIRE - POT
Summary of Contents for Euro Alpi Vezzana
Page 1: ...Use and maintenance manual for pellet stove...
Page 42: ...16 Notes...