Check that the thermal protection of the tank didn't activate, if it
has intervened please make sure that there are no obstructions
at the back and front openings of the stove or to the air outlet
grill, which block the right passage of air. Once this is done, reset
the safety thermostat, which is located in the back of the stove
(
Figure 27
), under the general switch, covered by a plastic lid
screwed on, remove the cap, press the button, put the cap back;
restart the stove and check if the environment fan is working
correctly. If the alarm persists, call the Authorized Service
Provider.
Figure 27
12.8 Alarm absence depression
It occurs when the external pressure switch component detects a pressure/depression below the trigger
threshold. The pressure switch intervenes by turning the auger off, being these two electrically connected in
series, and the controller signals the alarm status (alarm LED on) displaying " AL 8 ALAR AL 8 FAILURE
DEPRESS” (
Figure 28)
on the display. The stove turns off. Remove voltage, clean carefully: the brazier, the
combustion chamber, the passage of smoke and the flue; if the alarm persists, call the Authorized Service
Provider.
Figure 28
12.9 Display message SERV
When the message "SERV" appears, the stove has reached 1500 hours of operation. We recommend that
you call your authorized service center for routine maintenance. (F
igure 29
)
Figure 29
Al 8 alar al 8 FAILURE DEPRESS
serv