background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

16 Notes 

Summary of Contents for Euro Alpi Vezzana

Page 1: ...Use and maintenance manual for pellet stove...

Page 2: ...t considered in the manual and not authorized by a technician recommended by the company must be considered dangerous Otherwise the ZF company does not assume any responsibility both civil and crimina...

Page 3: ...ny ZF is released from any civil or criminal responsibility Before performing any operation the user must have read and understood all the contents of this manual of Use and Maintenance Tampering and...

Page 4: ...he use of the stove all the local and national and all European standards must be met 5 Warranty Warranty conditions ZF s r l located in Dino Fochesato Street n 1 Meledo of Sarego VI guarantees its pr...

Page 5: ...es The above warranty terms have not been observed The installation is not carried out in full obedience of the laws in force and the instructions contained in the provided manual Non maintenance or w...

Page 6: ...om the warranty and they are Gaskets Ceramic tempered glass Upholstery and grills Varnished details Chromate gilded Satinized Majolica Handles Electric cables Vermiculite Refractory material Brazier C...

Page 7: ...ion errors Non compliance with safety regulations Installation by unqualified and untrained personnel Installation not in accordance with the regulations in force in the country Use of non original sp...

Page 8: ...ence of a suitable fumes evacuation system It is not compulsory to connect the air intake tube of the stove directly outside see picture but it is recommended for a better efficiency energy saving In...

Page 9: ...nspection it is advisable to use curves of 45 Using nets or filters at the extremity of the flue or any extremity which could turn into a nest is forbidden Use only extremity in accordance with the re...

Page 10: ...e it must have a preferably circular internal section the square or rectangular sections must have rounded corners with a radius of at least 20mm the rectangular sections with a maximum ratio of 1 5 b...

Page 11: ...assured windproof chimney pot The chimney pot must be positioned to guarantee an adequate dispersion and dilution of the combustion products and however outside the reflux area This area has differen...

Page 12: ...and consequently in the opposite situation increases the depression decreasing the draught To overcome these drawbacks the installer must act directly on the stove modifying the parameter to adjust t...

Page 13: ...at rated power 104 6 C Fumes temperature at reduced power 68 4 C Carbon dioxide at rated power 6 89 Carbon dioxide at reduced power 4 95 CO at 13 O at rated power 140 8 mg m CO at 13 O at reduced pow...

Page 14: ...nal First steps Check that there are no objects on the stove manual included and proceed as follows Fill the hopper with pellets opening the upper door and closing it again making sure that no foreign...

Page 15: ...temperature SET room PROGRAMMING It decrements the selected parameter SET POWER Decrement of the value of the work power 2 Increment power SET TEMPERATURE It increments the value of the temperature SE...

Page 16: ...taller must make the first start by taking precautions and must ensure that the safeties are working properly pressure switch hopper temperature protection etc Any anomalies with the installation can...

Page 17: ...ellet loading After about 1 minute the pellet loading phase begins the message LOAD PELLET passes on the display and the ON OFF LED flashes In a first step the auger provides to load the pellets in th...

Page 18: ...the value contained in PR13 and maintained it for at least a time PR02 the stove goes into working mode which is the normal operating The display will show the word Work and the LED ON OFF is on The p...

Page 19: ...lay shows the set room temperature SET temperature Thus acting on the buttons P1 decrease and P2 increase it is possible to change the value After about 5 seconds the value is saved and the display re...

Page 20: ...the stove has turned off the auger auger LED off the exchanger switches off when it reaches the threshold given by the parameter PR15 and the LED ON OFF flashes Figure 10a Figure 10a When the fumes te...

Page 21: ...t 10 minutes During this time the pressure on the P3 button does not generate any answer by the system Figure 11a 11 THE MENU You can enter the menu with a prolonged pression on the P1 button The menu...

Page 22: ...sday Prg 2 on off 15 Wednesday Prg 2 on off 16 Thursday Prg 2 on off 17 Friday Prg 2 on off 18 Saturday Prg 2 on off 19 Sunday Prg 2 on off 20 start Prg 3 OFF 0 23 50 21 stop Prg 3 OFF 0 23 50 22 Mond...

Page 23: ...3 Thermostat state info 04 Fumes state info 05 Fumes extraction revolutions state info Level 1 Level 2 Value M8 technician settings 01 access key set Level 1 Level 2 Value M9 exit 01 exit set 11 2 Men...

Page 24: ...figure 12b the minutes figure 12c the day figure 12d the month figure 12e and the year figure 12f by pressing the P1 button decrement and P2 button increment and confirming by pressing the P3 button F...

Page 25: ...3a Figure 13a You can set two sections of functioning the first one with START1 Day and STOP1 Day and the second one with START2 Day and STOP2 Day delimitated by the times set according to the followi...

Page 26: ...on off M2 3 05 TUESDAY PRG 1 on off M2 3 06 WEDNESDAY PRG 1 on off M2 3 07 THURSDAY PRG 1 on off M2 3 08 FRIDAY PRG 1 on off M2 3 09 SATURDAY PRG 1 on off M2 3 10 SUNDAY PRG 1 on off PROGRAM 2 Menu le...

Page 27: ...tton decrement or P2 button increment You can set the period of functioning for Saturday by setting Start1 weekend and Stop1 weekend while you can set the functioning of the stove for Sunday by settin...

Page 28: ...1 or P2 to enable or disable press P3 to confirm Figure 16 11 7 Menu M6 First load This function is available only when the stove is turned off and allows to load the auger at the first ignition of th...

Page 29: ...te 52 Time out Toff Thermostat state 106 Fumes temperature 1490 Fumes extraction speed 11 9 Menu M8 Technician settings This menu entry is for the technician who installs the stove After having put th...

Page 30: ...tion causes the immediate turning off of the stove The alarm state is reached after the time PR11 EXCEPT THE ALARM OF BLAC OUT and can be reset by pressing and holding the button P3 Whenever an alarm...

Page 31: ...The display shows the message AL 3 ALAR AL 3 HOT EXHAUST as in Figure 22 and the stove goes off Electrically disconnect the stove and call your authorized service center Figure 22 12 4 Encoder smoke...

Page 32: ...s when in working phase the smokes temperature decreases below the parameter PR13 The message AL 6 ALAR AL 6 NO PELLET will pass on the display and the stove goes into alarm state Figure 25 Figure 25...

Page 33: ...larm absence depression It occurs when the external pressure switch component detects a pressure depression below the trigger threshold The pressure switch intervenes by turning the auger off being th...

Page 34: ...Call an authorized service The flame did not bring the fumes on right temperature within the preset time The pellet is finished reload the tank switch the stove on if the problem persists call the au...

Page 35: ...n the ash reaches the edge of the same drawer it is strictly forbidden to light the stove if the ash goes beyond it Every day when you clean the brazier also check if the drawer has to be emptied This...

Page 36: ...to the inner sides of the stove Remove the brazier to proceed with the removal of interior sides Remove the internal combustion chamber surround taking it by the two lower edges if this operation is d...

Page 37: ...behind the support of the brazier there is another combustion chamber surround to remove it grab it by the edge and pull up Removed this part the two rear combustion chamber surrounds are released to...

Page 38: ...ing and physical state Do not reassemble broken or damaged parts that may cause the malfunction of the stove Summary scheme of the cleaning and maintenance of the stove Daily Every 3 days Every 15 day...

Page 39: ...al arising from the use of non original spare parts also informs that the use of these implicates the fall of the warranty on the stove You will find the complete list of spare parts and related code...

Page 40: ...glia aria sx 1 38 R2600444 Marchio Euro Alpi 1 39 R2600445 Staffetta 50x40x33 20 10 4 40 R2600446 Supporto interruttore 1 41 R2600447 Maniglia porta EA 1 42 R2600448 Top anteriore 1 43 R2600449 Portel...

Page 41: ...Below the diagram for the connection between the different electric parts and the motherboard of the stove is represented TSP safety thermostat pellet tank 15 Wiring diagram...

Page 42: ...16 Notes...

Page 43: ...Notes...

Page 44: ...ixed municipal waste but it must be assigned to specialized collection structures as prescribed by local regulations or by the dealer The importer and the dealer are responsible for collection and dis...

Reviews: