- 4 -
D T5803
D T5804
D T 5801
D T5806
D T5802
D T5805
D T5807
D T5808
200
Ω
2K
Ω
20
Ω
200K
Ω
2M
Ω
20M
Ω
200M
Ω
A ccuracy
R ange
—
± [5% *(R -10)+ 10]
±(1.0% ±10)
± (1.0% ± 4)
±(1.0% ±10)
±(0.2% ±20)
±(0.2% ±10)
±(0.2% ±20)
7) TEMPERATURE (DT5807 & DT5808 only)
D T 5807 D T 5808
-4 0
℃
~ 4 0 0
℃
400
℃
~ 1000
℃
A ccuracy
R ange
±(1.0% +4)
± (1.5% +15)
With K-type thermocouple wire
8) FREQUENCY
TEST
D T 5801 D T 5802 D T 5803 D T 5804 D T 5805 D T 5807 D T 5806 D T 5808
2K H z
20K H z
—
—
±(3.0% +5)
A ccuracy
R ange
—
±(3.0% +5)
Sensitivity: 100mV rms
4.
PRECAUTIONS AND PREPARATIONS FOR MEASUREMENT
1) Be sure that battery is correctly placed in the battery case and
connected to the battery snap.
2) Don’t exceed the input limit shown below:
Function Range
Input terminals
Maximum input
DCV 200mV
250VDC
ACV 200mV
250VAC
DCV 2~1000V
1000VDC
ACV 2~750V
750VAC
OHM
V/OHM COM
Freq.
V/OHM/Hz COM
Logic
V/OHM COM
Diode
V/OHM COM
DCA 200mA
ACA 200mA
DCA 2A
ACA 2A
DCA 20A
20A COM
20A DC/AC
V/OHM COM
250V DC/AC
A COM
200mA DC/AC
2A DC/AC
3) Inspect the test leads for damaged insulation or exposed metal. Check
Test lead continuity. Damaged leads should be replaced.
4) Select the proper function and range for your measurement.
5) Check the input terminal position for red test lead depends on
measurement ranges.
6) Either one of the test leads should be taken off from the circuit under