background image

17

hurrimix

The reference figures are present on pages 3, 4, 5 and 6 of this manual and in the product Quick Guide.

 

EN

 

• 

it is prohibited to work objects with features different from those 
for which the equipment has been designed

;

• 

in  the  event  of  a  malfunction  follow  the  advice  given  in  this 

manual;  if  in  doubt,  stop  the  equipment  and  contact  your 

Authorised After-Sales Centre immediately

;

• 

do not open equipment compartments containing electric parts

;

• 

before  carrying  out  any  cleaning,  routine  and/or  extraordinary 
maintenance, make sure that the equipment has been unplugged 
from the mains power supply

;

• 

do  not  replace  the  power  supply  cable  or  tamper  with  the 

supplied plug; to replace the same due to damage or wear, only 

contact the  Authorised After-Sales Centre

;

• 

always  make  sure  that  there  are  no  foreign  bodies  inside  the 
work area. These could prevent damage to the equipment and/or 
injury to the staff

;

•  do not use petrol or flammable solvents as detergents; use only non-

flammable, non-corrosive and non-toxic substances. (see par. 8.1).

Zhermack  S.p.A.  cannot  be  held  responsible  for  any 
damage to the equipment owing to incorrect maintenance 
performed  by  unskilled  staff  or  maintenance  that  does 
not comply with that stated in this manual.
As  of  this  moment  Zhermack  S.p.A.  is  relieved  from 
any injury/damage to persons/objects that should occur 
following any different use and use not declared in this 
manual.

In the event of a fire - no matter how small - inside the 
equipment or nearby, only use powder extinguishers. Do 
not use water.

ChAPTER 3:   DESCRIPTION OF ThE EqUIPMENT

3.1 

GENERAL DESCRIPTION OF ThE EQUIPMENT

The device described in this manual is the 

hurrimix 

mixer, designed 

for mixing automatically alginates and plasters for dental use.

3.2 

DESCRIPTION OF ThE COMPONENTS - 

Fig. A

 1.  Lid 
 2.  Centrifugal compartment 
 3.  Digital display
 4.  Main switch 
 5.  Main power socket
 6.  Main power cable
 7.  On/Off button
 8.  Program button
 9.  Button “+” mixing time
 10.  Button “-” mixing time

 11. START/STOP button 

3.3 

IDENTIFICATION DATA

Fig. B:

 the equipment described in this manual has a plate giving 

identification data of the same and the Manufacturer:

Name and address of the Manufacturer

Equipment code and model

Serial number

Power supply information

The  equipment  has  been  built  in  compliance  with  the  EEC 
Directives  stated  in  the  attached  “CE  Declaration  of  Conformity. 
Use the identification data to request spare parts, information and 
After-Sales Assistance from authorised centres. If the plate should 
deteriorate with use and become illegible, even partially, request a 
replacement from the Manufacturer stating all data.

Do  not  remove  and/or  ruin  the  plate  so  that  the 
equipment  identification  data  can  be  recognised  at  all 
times.

ChAPTER 4:   TEChNICAL FEATURES

4.1 

TEChNICAL FEATURES AND FUNCTIONING PRINCIPLE

Zhermack S.p.A. creates qualitatively and technologically advanced 
work instruments, in away that the user feels that they are made-
to-measure his everyday working requirements.
Zhermack S.p.A. uses state-of-the-art instruments in the design field 
when making these products, thus ensuring maximum equipment 
functionality. The use of top quality materials and performance of 
all  inspections  necessary  for  operator  safety  guarantee  Zhermack 

S.p.A products, making them competitive at a worldwide level.
The operating principle that characterises 

hurrimix

 mixer is based 

on  the  mixing  alginates  and  plasters  for  the  dental  industry.  The 
device offers the following advantages:

• consistent mixing quantity;
• even mixture;
• mixing time is significantly reduced compared to manual mixing;
• software with 20 mixing programs (that can be customised by the 

user): 10 programs for alginate and 10 for plasters, some of them 

are preset to be used with Zhermack products;
• programming and mixing are easy to manage, thanks to the large 
digital display;
•  the  cover  can  be  customised  in  6  colours  to  blend  in  with  the 

decor of the Dental Clinic.

4.2 

TEChNICAL DATA

Technical data relative to the 

hurrimix 

mixer: 

Power voltage                                                  230 V ~ ± 10% 50/60Hz
 

 115 V ~ ± 10% 50/60Hz

Absorbed power  

 

  400 Watt

Protection rating IP  

 

  IPX0

Noise level  

 

  <70 dB

Overvoltage category  

 

  II

Applicable pollution degree  

 

  2

4.2.1 

STANDARD SUPPLIES

 - Fig. C

As well as this Use and Maintenance Manual and the quick guide 
the 

hurrimix

 mixer is also supplied with:

Components 

 

 

Q.ty 

    Code*

12. Containers for alginate mixing 

 

XR0250800

13. Containers for plaster mixing 

 

XR0250810

14. Set of spatulas 

 

 

XR0250820

15. Pre-mix stick 

 

 

XR0250830

16. Bottle with graduated measuring cup   

XR0250840

(*) Order Code to be used when ordering spare parts.

4.2.2 

ACCESSORIES AVAILABLE ON REQUEST

 - Fig. D

Kit of interchangeable covers:

Components 

 

 

Q.ty 

    Code*

White (Standard) 

 

XR0250850

Azure (on request) 

 

XR0250855

Orange (on request) 

 

XR0250860

Blue (on request) 

 

XR0250865

Green (on request) 

 

XR0250870

Grey (on request) 

 

XR0250875

(*) Order Code to be used when ordering spare parts.

4.2.3 

WEIGHT AND OVERALL CLEARANCE

Overall clearance without packaging
Height (h)  

  

        cm. 31

Height with door open (max. h)  

  

        cm. 50

Width (l)  

  

        cm. 24

Depht (p)  

  

        cm. 30

Empty weight  

  

        Kg. 21

ChAPTER 5:   TRANSPORT AND hANDLING

5.1 

GENERAL WARNINGS

In  order  to  prevent  injury/damage  to  persons/objects, 
pay  great  care  when  handling  the  equipment, 
scrupulously  complying  with  all  precautions  and 
instructions contained in the following paragraphs.

5.2 

PACKAGING AND UNPACKING

Fig.  E: 

All  material  is  carefully  controlled  by  the  Manufacturer 

before delivery. On receiving the equipment, make sure that it has 
not  been  damaged  during  transport  and  that  the  packaging  has 
not been tampered with, resulting in missing parts. 
Should any damage or missing parts be noted, inform the Dealer 
and the Carrier immediately by forwarding photographic evidence. 
The packaging, made up of a cardboard box with expanded plastic 
internal protections, contains:

• the 

hurrimix

 mixer;

• the material supplied (see par. 4.2.1);
• the Use and Maintenance Manual.
• the quick guide.

Summary of Contents for Hurrimix

Page 1: ...t e R o c k E l i t e M a s t e r E l i t e M o d e l E l i t e S t o n e E l i t e M o d e l F a s t E l i t e A r t i P r o g 1 P r o g 2 P r o g 3 P h a s e P l u s H y d r o c o l o r 5 A l g i n...

Page 2: ......

Page 3: ...hurrimix 3 4 5 6 1 2 8 7 9 10 11 3 13 14 15 12 16 A C A B C D BEYOND INNOVATION ZHERMACK SpA Badia Polesine RO Italy C303230 HURRIMIX 230V SN xxxxxxxx 230V 50 60Hz 400W B D h u rr im ix E F...

Page 4: ...tus Elite Ortho Elite Rock Elite Master Elite Model Elite Stone Elite Model Fast Elite Arti Prog 1 Prog 2 Prog 3 Phase Plus Hydrocolor 5 Alginates Hydrogum 5 Hydrogum Tropicalgin Mixing Time sec 06 Or...

Page 5: ...o p r in t N e o c o ll o id P r o g 1 P r o g 2 P r o g 3 10 7 2 3 sec 8 Dental Stones Status Elite Ortho Elite Rock Elite Master Elite Model Elite Stone Elite Model Fast Elite Arti Prog 1 Prog 2 Pro...

Page 6: ...g and unpacking 5 3 Transport and handling 5 4 Disposal Dismantling 6 INSTALLATION AND COMMISSIONING 6 1 Warnings and precautions 6 2 Accepted environmental conditions 6 3 Space necessary for use 6 3...

Page 7: ...der to guarantee your safety and that of others and to prevent damage to the equipment Any operations carried out without compliance to instructions or tampering with equipment parts which can cause d...

Page 8: ...hnologically advanced work instruments in away that the user feels that they are made to measure his everyday working requirements Zhermack S p A uses state of the art instruments in the design field...

Page 9: ...keep the original packaging so that if necessary it can be re used for transport and handling the equipment thus preventing accidental damage due to the use of unsuitable packaging see paragraph 5 3...

Page 10: ...Stones only recommended quantity 80g max 100g Do not exceed the maximum permitted quantity to avoid malfunction Once it has been correctly installed and put into service proceed as follows Fig 13 Pre...

Page 11: ...ASTER CONTAINER Rinse the container and cover before the mixture hardens Gently clean the surfaces with non alcohol based products Do not use inflammable corrosive alkaline or toxic liquids to clean t...

Page 12: ...g from poor maintenance incorrect power supply negligence inexperience and other causes not imputable to the Manufacturer and parts subject to normal wear are not covered by the warranty The warranty...

Page 13: ...22 hurrimix The reference figures are present on pages 3 4 5 and 6 of this manual and in the product Quick Guide EN 10 3 TECHNICAL INTERVENTIONS SHEET Date Description of the interv Signature...

Page 14: ......

Page 15: ...XM2501510 Rev 05 12 ww w tec nomedia biz...

Reviews: