IMACS System Release 5.1.9
Reference Guide
Model No.
Running Head
PVC has user circuits active. No changes allowed.
You cannot deactivate a Frame Relay PVC with active user circuit(s).
PVC name must be entered.
You must enter a PVC name before executing this command.
PVC name must be unique.
The current PVC name is already in use. Enter a different name.
RATE = 19.2 must have DATA = 8 for adpcm or hlink.
If you set the SRU card port rate to 19.2 kbps, you also must set the number of data bits for
that port to 8.
Redundancy requires WAN Model 8014 in Slot W4.
Your system must have an 8014 WAN Card in slot W4 for WAN redundancy operation.
Redundancy switchover is complete.
You have asked the system to switch to the redundant WAN card, and the switchover was
successfully completed. (This is not an error message; it normally appears after you initiate
the switchover.)
Redundant CPU.
The current CPU card is the redundant card.
Redundant WAN is taken already.
You cannot switch to the redundant WAN card in slot WAN-4 if it is already in use from a
previous WAN card switch.
Remote session active. Can’t change setting.
You cannot change this setting because a remote operator has accessed the system and is
controlling it. Wait for that operator to log off and disconnect.