General Features
4-21
IMACS-200 General Features
Remote Administration
RPT3 IP ADDR
The RPT3 IP Address is the IP address of the third Network Management System host running
an SNMP trap server.
RPT3 COMMUN STR
The RPT3 Community String holds the community string for the third NMS host running a
SNMP trap server. The community string provides additional security by rejecting messages
that do not contain the correct string. There must be an entry in this field to enable RPT3.
4.7
Remote Administration
The Ethernet port allows the user to telnet into the IMACS-200 and allows for remote
management, configuration and downloading of host code via a 10baseT Ethernet port.
4.7.1
Setting Up Remote Connectivity
Before using the remote Ethernet port, the crafts person must perform the following steps:
1. From the CPU Main screen in Figure 4-2, enter ‘I’ for tcp/Ip, as seen in figure Figure 4-11.
Figure 4-11.Setting up Remote Connectivity
2. Leave the HOST IP STATE as stdby for now.
3. Enter in the HOST IP ADDRESS: [device IP address]
Summary of Contents for IMA CS-200 System
Page 18: ...8 Table of Contents Model No Running Head Table of Contents...
Page 22: ...4 List of Figures Model No Running Head List of Figures...
Page 130: ...4 46 General Features Model No Running Head CPU Troubleshooting IMACS 200 General Features...
Page 148: ...5 18 WAN Ports Model No Running Head WAN port Troubleshooting WAN ports...
Page 202: ...9 14 High Speed Data Ports Model No Running Head...
Page 208: ...10 6 OHSU Ports Model No Running Head...
Page 230: ...12 16 IPR Model No Running Head IPR Configuration Screens and Settings IP Routing...
Page 264: ...A 12 System Standards and Specifications Model No Running Head IPR Server Specifications...
Page 274: ...B 10 Error Messages Model No Running Head...
Page 294: ...20 Glossary Model No Running Head Zero Code Suppression...