7-12
E&M Ports
Model No.
Running Head
TEST
The Test parameter shows if the port is in test mode or not. Inactive ports and ports that are
assigned to inactive WANs will show a test status of n/a. The test status options for active
ports are off and on.
Tx ABCD
The Transmit ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being transmitted towards the network or set a specific ABCD pattern for testing the
transmit side of the circuit. The options for this field are mon (monitor) or set. Choosing set
will bring up a four digit field for users to input the ABCD pattern they want to transmit. Any
four-digit combination of ones and zeros is acceptable for this setting.
Rx ABCD
The Receive ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being received from the network or set a specific ABCD pattern for testing the receive
side of the circuit. The options for this field are mon (monitor) or set. Choosing set will bring
up a four digit field for users to input the ABCD pattern they want to receive. Any four digit
combination of ones and zeros is acceptable.
E-lead
The E-lead setting allows the user to either monitor or set the state of the E-lead. The options
for this field are mon (monitor) or set. Choosing set will bring up the options on (which raises
the E-lead), or off (which drops the E-lead.
Rx ABCD
mon set
mon
E-Lead
mon
mon
TO USER
none D-mW
none
TO NTWK
none D-mW
none
Tx ABCD
Status information only; not editable
n/a
Rx ABCD
Status information only; not editable
n/a
E-lead
Status information only; not editable
M-lead
Status information only; not editable
MODE
Status information only; not editable
n/a
TYPE
Status information only; not editable
n/a
STATUS
Status information only; not editable
n/a
Summary of Contents for IMA CS-200 System
Page 18: ...8 Table of Contents Model No Running Head Table of Contents...
Page 22: ...4 List of Figures Model No Running Head List of Figures...
Page 130: ...4 46 General Features Model No Running Head CPU Troubleshooting IMACS 200 General Features...
Page 148: ...5 18 WAN Ports Model No Running Head WAN port Troubleshooting WAN ports...
Page 202: ...9 14 High Speed Data Ports Model No Running Head...
Page 208: ...10 6 OHSU Ports Model No Running Head...
Page 230: ...12 16 IPR Model No Running Head IPR Configuration Screens and Settings IP Routing...
Page 264: ...A 12 System Standards and Specifications Model No Running Head IPR Server Specifications...
Page 274: ...B 10 Error Messages Model No Running Head...
Page 294: ...20 Glossary Model No Running Head Zero Code Suppression...