E&M Ports
7-15
7.4
E&M port Error Messages
Refer to Appendix B in the System Reference Guide for further information on Error
Messages regarding this port.
7.4.1
E&M port Troubleshooting
The E&M port may be faulty if a voice signal is not received at one end of a circuit, or if E&M
signaling is not detected. The following are possible causes:
•
Faulty receiving CPE at the near end (where the problem was first noticed)
•
Faulty transmitting CPE at the far (opposite) end
•
Faulty cabling between the CPE and E&M port at either end
•
Faulty E&M port at either end
•
T1 network failure
•
Improper port configuration at either end (e.g., time slot and/or WAN assignments)
First, verify that the T1 network has not failed. Check for a CGA-Red alarm on the associated
WAN port at the end where the incoming VF signal loss is first noticed. The CGA indicates
that the incoming network signal was lost (or that the receiving WAN port is out of frame).
During the CGA, all voice ports with time slots on that WAN port will also be disabled, and
the associated far-end WAN port will be in a CGA-Yellow alarm state. If the network is faulty,
you must clear that trouble to restore your circuits.
If the network is okay, verify that the proper WAN ports and time slots are assigned to the
associated E&M voice ports at both ends, as previously outlined in this chapter. In a
point-to-point network, the near-end and far-end E&M ports should both be assigned the same
WAN port and time slot number. Also make sure the other parameters (such as the transmit
and receive TLPs) are set properly at both ends.
If the E&M port parameters are correct at both ends, and if the network is okay, the trouble is
isolated to the E&M port or the associated port. Proceed as follows:
1. At the far end, activate an analog loopback on the E&M port.
2. Send a 0 dBm (digital milliwatt) test signal toward the CPE at that end. That signal will
be substituted for the normal signal coming from the far-end CPE; it will be sent back to
the CPE at your end via the loopback path.
3. Check your CPE for this signal. If it is present, the far-end CPE or cabling to the far-end
E&M port is probably faulty. Disable the loopback and test signal there, and fix the
problem. If you still don’t receive a signal, go to step 4.
Summary of Contents for IMA CS-200 System
Page 18: ...8 Table of Contents Model No Running Head Table of Contents...
Page 22: ...4 List of Figures Model No Running Head List of Figures...
Page 130: ...4 46 General Features Model No Running Head CPU Troubleshooting IMACS 200 General Features...
Page 148: ...5 18 WAN Ports Model No Running Head WAN port Troubleshooting WAN ports...
Page 202: ...9 14 High Speed Data Ports Model No Running Head...
Page 208: ...10 6 OHSU Ports Model No Running Head...
Page 230: ...12 16 IPR Model No Running Head IPR Configuration Screens and Settings IP Routing...
Page 264: ...A 12 System Standards and Specifications Model No Running Head IPR Server Specifications...
Page 274: ...B 10 Error Messages Model No Running Head...
Page 294: ...20 Glossary Model No Running Head Zero Code Suppression...