Sub Rate Data Ports
8-9
SRU Ports
Test Screen
Table 8-4. Test Screen Actions
Table 8-5. Test Screen Option Settings and Defaults
BERT
Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER) on the
selected SRU port. The patterns that can be selected are off, mark (all ones), space (all zeros),
1:1 (alternating 10101010), 1:7 (10000000), 511 (511 test pattern), and 2047 (2047 test
pattern).
DIR
The Direction (DIR) setting allows you to specify where the BERT test signal should be
directed. The first option is net (network) which means that the test signal will be transmitted
through the system toward the Wide Area Network (WAN). The user option means that the
signal will be directed toward the attached DTE device over the RS-232 interface.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically
updated (i.e., test status).
InsertErr
Allows you to manually insert a single error into the clear data signal.
Clear
Clears the Test Screen and resets all counters to zero.
Main
Returns to the SRU port Main Screen. If changes are made to settings and
not saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
BERT
off mark space 1:1 1:7 511 qrss 2047
off
DIR
net user
net
CTS
norm off on
norm
RLSD
norm off on
norm
SYNC
information only–no user options
*****
BE
information only–no user options
*****
ES
information only–no user options
*****
SES
information only–no user options
*****
CSES
information only–no user options
*****
OSS
information only–no user options
*****
BER
information only–no user options
*****
ELAP
information only–no user options
*****
RTS
information only–no user options
*****
SR OSS
information only–no user options
*****
LB ST
information only–no user options
*****
Summary of Contents for IMA CS-200 System
Page 18: ...8 Table of Contents Model No Running Head Table of Contents...
Page 22: ...4 List of Figures Model No Running Head List of Figures...
Page 130: ...4 46 General Features Model No Running Head CPU Troubleshooting IMACS 200 General Features...
Page 148: ...5 18 WAN Ports Model No Running Head WAN port Troubleshooting WAN ports...
Page 202: ...9 14 High Speed Data Ports Model No Running Head...
Page 208: ...10 6 OHSU Ports Model No Running Head...
Page 230: ...12 16 IPR Model No Running Head IPR Configuration Screens and Settings IP Routing...
Page 264: ...A 12 System Standards and Specifications Model No Running Head IPR Server Specifications...
Page 274: ...B 10 Error Messages Model No Running Head...
Page 294: ...20 Glossary Model No Running Head Zero Code Suppression...