High Speed Data Ports
9-11
Table 9-5. Test Screen Option Settings and Defaults
BERT
The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER)
on the selected HSU port. The patterns that can be selected are off, mark (1111), space (0000),
1:1 (1010 alternating), 1:7 (0100-0000), 3:24, qrss (quasi-random signal source),
prb11(pseudorandom binary sequence), prb15 and prb20.
SYNC
The Synchronization field indicates if the integrated BERT has achieved synchronization
either with itself via a remote loopback or with the remote test equipment. This is an
information-only field; it is not user-configurable.
BE
The Bit Error (BE) field indicates the total number of bit errors logged. This is an
information-only field; it is not user-configurable.
ES
The Errored Seconds (ES) field indicates the total number of seconds in which errors were
detected. This is an information-only field; it is not user-configurable.
Parameter
User Options
Notes
Default
BERT
off mark space 1:1 1:7 3:24 qrss prb11
prb15 prb20
off
DIR
net user
net
SYNC
information only–no user options
BE
information only–no user options
ES
information only–no user options
SES
information only–no user options
CSES
information only–no user options
OSS
information only–no user options
BER
information only–no user options
ELAP
information only–no user options
LB ST
information only–no user options
Summary of Contents for IMA CS-200 System
Page 18: ...8 Table of Contents Model No Running Head Table of Contents...
Page 22: ...4 List of Figures Model No Running Head List of Figures...
Page 130: ...4 46 General Features Model No Running Head CPU Troubleshooting IMACS 200 General Features...
Page 148: ...5 18 WAN Ports Model No Running Head WAN port Troubleshooting WAN ports...
Page 202: ...9 14 High Speed Data Ports Model No Running Head...
Page 208: ...10 6 OHSU Ports Model No Running Head...
Page 230: ...12 16 IPR Model No Running Head IPR Configuration Screens and Settings IP Routing...
Page 264: ...A 12 System Standards and Specifications Model No Running Head IPR Server Specifications...
Page 274: ...B 10 Error Messages Model No Running Head...
Page 294: ...20 Glossary Model No Running Head Zero Code Suppression...