13-6
OWAN Ports
Model No.
Running Head
SIG STATUS
This field reflects that status of the optical link. Possible values indicate loss of signal (los),
normal (norm)
SIGTYPE
This read-only field indicates the type of signaling employed on the optical link. possible
values are ds2 and e2.
13.4.1 Port Settings for OWAN
Figure 13-4 shows the screen displaying the four DS1 or E1 ports and their respective settings.
Figure 13-4.Typical Settings for the T1 OWAN Ports
Table 13-3. OWAN Port Setting Options and Defaults for T1
Parameter
User Options
Default
STATE
stdby actv
stdby
Format
d4 esf
esf
Line LB
off on
off
Local LB
off on
off
LB GEN
off llb plb
off
LB DET
off on w/to
off