Error Messages
B-1
Appendix B
Error Messages
B.1
Introduction
This appendix lists the IMACS-200 error messages. One of these messages may appear at the
bottom of the screen when you enter a command, indicating that the system did not perform
the requested action. This condition may have been caused by an operator error, absence of a
port in the system, or other condition. If an error message appears, take the appropriate
corrective action. For convenience, the system error messages are listed alphabetically.
A name must be assigned to Circuit ID field.
You must enter a name for the circuit before attempting this operation. Go to the Circuit ID
field, type the desired name, and save it.
All blank prt report.
You chose the empty option setting for all four elements of the Print Alarm on the Interface
port. This combination of settings is invalid and cannot be saved. Choose the proper option
settings for these elements.
ASYNC/5 databits must have 2 stop or parity.
You have assigned an SRU port to an asynchronous circuit with 5 data bits, one stop bit, and
no parity. This is an invalid combination of option settings. Either choose two (2) stop bits, or
enable parity on that port.
Both WAN’s cannot be in test mode.
You cannot use the test option on both sides of a cross-connect simultaneously.
Cannot be STDBY while BERT test is running.
You cannot change a port from the actv (active) state to the stdby (standby) state while the Bit
Error Rate Tester (BERT) is running. You must end the BERT test first.
Summary of Contents for IMA CS-200 System
Page 18: ...8 Table of Contents Model No Running Head Table of Contents...
Page 22: ...4 List of Figures Model No Running Head List of Figures...
Page 130: ...4 46 General Features Model No Running Head CPU Troubleshooting IMACS 200 General Features...
Page 148: ...5 18 WAN Ports Model No Running Head WAN port Troubleshooting WAN ports...
Page 202: ...9 14 High Speed Data Ports Model No Running Head...
Page 208: ...10 6 OHSU Ports Model No Running Head...
Page 230: ...12 16 IPR Model No Running Head IPR Configuration Screens and Settings IP Routing...
Page 264: ...A 12 System Standards and Specifications Model No Running Head IPR Server Specifications...
Page 274: ...B 10 Error Messages Model No Running Head...
Page 294: ...20 Glossary Model No Running Head Zero Code Suppression...